Read Sharp AR-5132 (serv.man66) Technical Bulletin online
Page( 4 / 6 )
10.Assemble the part that has been disassembled in Step 1 above. (Modification of Fuser unit
has now been achieved.)
Once again check D-curler Belts to make it certain that they are located properly.
Then insert Fuser Unit into machine.
Once again check D-curler Belts to make it certain that they are located properly.
Then insert Fuser Unit into machine.
[Machine Main Unit]
11.Attach Fuser Lower PG (No. 21) × 3 to the plate located under Fuser Unit.
11.Attach Fuser Lower PG (No. 21) × 3 to the plate located under Fuser Unit.
12.Fit Reversal Protection Plate (No.25) to Front Frame with screw (No.26).
Attach Fuser Lower PG to Transport Plate
located right under the place where Fuser
Unit is to be inserted.
Unit is to be inserted.
130±1mm
144±1mm
250±1mm
Reference Line
The amount of the section going off Reference Line must be within 1mm on the + side.
Any amount of the part must not go off Reference Line on the side.
Reversal protection plate
Screw(M4X6)