AR-407 (serv.man4). AR287 337 407 507-Service Manual - Sharp Copying Equipment Service Manual (repair manual). Page 17

Read Sharp AR-407 (serv.man4) Service Manual online

8 - 7
Purpose
Adjustment/Operation test/check
Function
(Purpose)
Used to check and adjust the operation of the separa-
tion charger voltage and its control circuit.
Section
Image process
(Photoconductor/
Developing/Transfer/
Cleaning)
Others
Operation/
Procedure
The separation charger output voltage in printing the
front and the back of paper can be adjusted and
checked.
1. Select the print mode with [
­
] key and [
¯
] key.
2. Enter the adjustment value with the 10-key pad.
3. Press the [EXECUTE] key.
The [EXECUTE] key is highlighted, the adjustment value entered in
procedure 2 is set, and the voltage corresponding to the set value is
supplied.
After supplying the voltage for 30 sec, the [EXECUTE] key returns to
the normal display.
If the [EXECUTE] key is pressed while the voltage is supplied, the
voltage output is stopped and the [EXECUTE] key returns to the nor-
mal display.
FROMT MODE: Front surface print (with the paper feed tray and
manual paper feed tray)
BACK MODE: Back surface print (with duplex paper feed)
(AR-287/337)
(AR-407)
(AR-507)
22
22 - 1
Purpose
Operation data output/Check (Display/Print)
Function
(Purpose)
Used to check the print out count of each section in
each operation mode. 
(Used to check the maintenance timing.)
Item
Counter
Operation/
Procedure
nnnnnnnn : Counter value
22 - 6
Purpose
Operation data output/Check (Display/Print)
Function
(Purpose)
Used to output the list of the setting and adjustment
data (simulations, counters).
Item
Data
Adjust/Setting data
Operation/
Procedure
When installing or servicing, execute this simulation to
print and store the adjustment values and setting data
for use in the next servicing. (Memory trouble, PWB re-
placement, etc.)
In this case, the print conditions can be set optionally.
1. Select the setup item.
 (The selected item is highlighted.)
2. Set the item and conditions with the 10-key pad.
3. Press the [EXECUTE] key to print various data.
A: Paper feed mode
  1: Manual paper feed
  2: Upper paper feed tray
  3: Lower paper feed tray
  4: Desk upper paper feed tray
  5: Desk middle paper feed tray
  6: Desk lower paper feed tray
  7: Large capacity paper feed tray
26
26 - 10
Purpose
Setting
Function
(Purpose)
Used to allow entry of the software key input for the
network scanner.
Item
Operation
Operation/
Procedure
1. After entering the sub code of the simulation, enter
the software key in the obtained frame of "NEW."
2. When the obtained number is entered with the 10-key (max. 9 dig-
its), the entered number is displayed in the frame of "NEW." After
entering the number, press the [OK] key, and the entered number
is stored. 
3. Reset with the CA key, and the scanner function is enabled. 
*
Only when SCSI (20 channels/NS1) setup is completed.
If the scanner key input is made without setup, it is rejected.
4. Special note
AR-287/337
AR-407/507
7 – 53
4/5/2000
Page of 26
Display