AR-200 (serv.man5). AR200 Service Manual - Sharp Copying Equipment Service Manual (repair manual). Page 7

Read Sharp AR-200 (serv.man5) Service Manual online

2) Set the document size to A4, and make two copies at 100%.
3) Check the second copy. If necessary, perform the following ad-
justment procedure.
*
The first copy does not show the void. Be sure to check the
second copy.
4) Execute SIM 50-1 and set the density mode to AUTO + PHOTO
(Rear edge  void).
The currently set adjustment value is displayed.
5) Enter the set value and press the start key.
The correction value is stored and a copy is made.
<Adjustment specification>
Mode
SIM
LED
Set value
Specification
Set
range
Rear
edge
void
SIM
50-1
AUTO +
PHOTO
1 step:
0.127mm 
shift
4mm or less
 99
d. Paper off center adjustment
1) Execute SIM 50-1 and set the density mode of AUTO + MANUAL
(Left edge void) to 1.
2)  Set a test chart (UKOG-0089SCZZ) on the document table.
3) Select a paper feed port and make a copy.
Compare the copy and the test chart. If necessary, perform the
following adjustment procedure.
4) Execute SIM 50-10.
After completion of warmup, shading is performed and the cur-
rently set off center adjustment value of each paper feed port is
displayed.
5) Enter the set value and press the start key.
The correction value is stored and a copy is made.
<Adjustment specification>
Mode
SIM
LED
Set value
Specification
Set
range
Paper
off
center
SIM
50-10
AUTO +
MANUAL
Add 1:
0.127mm 
shift to R
side.
Reduce
1:
0.127mm 
shift to L
side.
Single:
Center
±
2.0mm
 99
Duplex:
Center
±
2.5mm
e. Left edge void area adjustment
Note: Before performing this adjustment, be sure to check that the
paper off center adjustment (SIM 50-10) is completed.
1) Set a test chart (UKOG-0089SCZZ) on the document table.
2) Select a paper feed port and make two copies.
Compare the second copy and the test chart. If necessary, per-
form the following adjustment procedure.
*
The first copy does not show the void. Be sure to check the
second copy.
3) Execute SIM 50-1 and set the density mode to AUTO + MANUAL
(Left edge void).
The currently set adjustment value is displayed.
(When the off center adjustment previously described is per-
formed, "0" is displayed.)
4) Enter the set value and press the start key.
The correction value is stored and a copy is made.
<Adjustment specification>
Mode
SIM
LED
Set value
Specification
Set
range
Left
edge
void
SIM
50-1
AUTO +
MANUAL
1 step:
0.127mm 
shift
0.5 
 4mm
 99
*
When the left edge void is set with the paper off center adjusted,
the both edge void is automatically adjusted.
(2) OC (SPF) open/close detection position adjustment
1) Set A4 or 8 1/2" 
×
 11" paper on the OC table.
Check that the document size display on the operation panel indi-
cates the correct size of the set paper.
2) Close the OC (SPF) with a small clearance for insertion of your
hand left, and remove the paper from the OC table.
The document size display does not change from the display in 1).
3) Open the OC (SPF) slowly until the display on the operation panel
changes (all the document size display lamps are turned off), and
measure dimension A shown below under that state.
<Spec value>
OC (SPF) open/close position A: 207 
 302mm
4) If the OC (SPF) open/close position A is not 207 
 302mm, adjust
the open/close sensor mounting plate position as shown below.
Scale image
Paper rear edge
Void amount (Standard value: 4mm or less) 
Open
A
Distance A = Table glass top - OC (SPF) knob 117"
Check the position where the display checked in 
procedure 1) is changed. 
(A)
(B)
Open/close sensor mounting plate
Factory setting : second from the top 
AR-200
4 – 3
Page of 23
Display