Read Sharp AR-200 (serv.man5) Service Manual online
9) Measure the distance H between the paper lead edge and the
image print start position. Set the image print start position set
value (Exposure display <EXP1> ON) again.
value (Exposure display <EXP1> ON) again.
•
1 step of the set value corresponds to about 0.127mm shift.
•
Calculate the set value from the formula below.
99 - H/0.127 (mm) = Image print start position set value <H: Print
start position measurement value (mm)>
start position measurement value (mm)>
Example: 99 - 5/0.127 = 99 - 39.4 = about 59
Note: If the set value is not obtained from the above formula,
perform the fine adjustment.
10)Set the main cassette lead edge void adjustment value (Exposure
display <PHOTO> ON)* again.
•
1 step of the set value corresponds to about 0.127mm shift.
•
Calculate the set value from the formula below.
B/0.127 (mm) = Lead edge void adjustment value <B: Lead edge
void (mm)>
void (mm)>
Example: When setting the lead edge void to 2.5mm:
2.5 /0.127 = about 20
Note: If the set value is not obtained from the above formula,
perform the fine adjustment.
*
Second cassette lead edge void adjustment: Exposure display
<AUTO + MANUAL + PHOTO>
Multi bypass tray lead edge void adjustment: Exposure display
<MANUAL + PHOTO>
<AUTO + MANUAL + PHOTO>
Multi bypass tray lead edge void adjustment: Exposure display
<MANUAL + PHOTO>
<Adjustment specification>
Adjustment
mode
SIM
LED
Set
value
Spec value
Set
range
OC image
lead edge
position
lead edge
position
SIM
50-1
AUTO
99
R/0.127
R/0.127
Lead edge
void: 1 -
4mm
Image loss:
3mm or less
void: 1 -
4mm
Image loss:
3mm or less
1
∼
99
Main
cassette lead
edge void
cassette lead
edge void
PHOTO
B/0.127
Second
cassette lead
edge void
cassette lead
edge void
AUTO +
MANUAL
+ PHOTO
Multi bypass
tray lead
edge void
tray lead
edge void
MANUAL
+ PHOTO
Print start
position
position
EXP1
99 –
H/0.127
H/0.127
b. SPF image lead edge position adjustment
1) Set a scale on the OC table as shown below.
Note: Since the printed copy is used as a test chart, put the scale in
paralled with the edge lines.
2) Make a copy, Then use the copy output as an original to make an
SPF copy again.
3) Check the copy output. If necessary, perform the following adjust-
ment procedures.
4) Execute SIM 50-1.
5) Set the SPF lead edge position set value (Exposure display
<MANUAL> ON) so that the same image is obtained as that
obtained in the previous OC image lead edge position adjustment.
obtained in the previous OC image lead edge position adjustment.
<Adjustment specification>
Adjustment
mode
SIM
LED
Set value
Spec value
Set
range
SPF image
lead edge
position
lead edge
position
SIM
50-1
MANUAL
1 step:
0.127mm
shift
0.127mm
shift
Lead edge
void: 1 -
4mm
Image loss:
3mm or less
void: 1 -
4mm
Image loss:
3mm or less
1
∼
99
c. Rear edge void adjustment
1) Set a scale as shown in the figure below.
5
10
0mm
0mm
*
Fit the print edge with the paper edge, and perform the
lead edge adjustment.
5
10
2.5mm
2.5mm
A4(8.5" x 11")
Paper rear edge
AR-200
4 – 2
Click on the first or last page to see other AR-200 (serv.man5) service manuals if exist.