AR-122E (serv.man9). Sect 10. Simulation Trouble Codes - Sharp Copying Equipment Service Manual (repair manual). Page 13

Read Sharp AR-122E (serv.man9) Service Manual online

AR-122E/152E/153E/157E  SIMULATION, TROUBLE CODES  10 - 13
48
01
Front/rear (main scanning) direction and scan (sub scanning) direction magnification ratio adjustment
(1) Front/rear direction magnification ratio auto correction: The width of the reference line marked on the shading correction plate is 
scanned to perform automatic correction of the front/rear (main scanning) direction magnification ratio as well as automatic setup of 
the OC/document center offset value and of the image scan start position.
In addition, the black level automatic adjustment is performed simultaneously.
The OC/document center offset value and the image scan start position automatically set in this simulation, can be checked by the 
respective manual setup simulation for each adjustment shown below.
(2) Front/rear direction magnification ratio manual correction: By key operations, the front/rear (main scanning) direction magnification 
ratio is set by changing the setup value of the ZOOM DATA register to AISC.
(3) Scan direction magnification ratio correction: The scan direction magnification ratio in the OC mode is set by changing the scan 
speed.
(4) SPF mode scan direction magnification ratio correction: The SPF mode scan direction magnification ratio is set by changing the 
scan speed.
(Operating procedure)
When this simulation is executed, the current setup value is displayed in two digits. (Center value: 50) Press the copy mode select key 
to select each setup mode and the setup display will change accordingly.
In the case of the front/rear direction automatic adjustment.
To perform the automatic adjustment, place the gray gradation chart (UKOG-0162FCZZ) face down so as to fit with the left center of the 
platen with the darker side (Density 10) on the left of OC.
When the PRINT switch is pressed, the mirror base unit moves to the shading white board, and the width of the reference line is 
scanned, and the correction value is calculated, and the value is saved.
After completion of the automatic adjustment, press the density adjustment Down key, and the black level will be displayed in 
hexadecimal number (3 digits) of 12bits.
For manual adjustment, enter the adjustment value with the 10-key and press the PRINT switch, the set value will be saved and a copy 
will be made. When the clear key is pressed, the value entered will be saved and the simulation will be terminated. (Increasing the 
setup value by 1 increases 0.1%.)
In the front/rear direction magnification ratio automatic correction
(1) When the calculated value of the scan correction value is within ±5%, “– –” is displayed.
(Cause) Erroneous position of the reference line on the white board, improper installation of the lens unit, etc.
(2) In case of a scan error of the reference line, the jam lamp lights up.
(Cause) CCD error, no white board installed.
If the automatic correction of the magnification ratio cannot provide a satisfactory result, use the manual correction.
Main 
code
Sub 
code
Content
OC/document center offset
Sim50-10
Center offset adjustment
Image scan start position
Sim50-01
Lead edge image position
10
1
Back of the chart
Adjustment mode
Lamp ON
Front/rear direction magnification ratio automatic correction and black level adjustment
AE lamp
Front/rear direction magnification ratio manual correction
TEXT lamp
Scan direction magnification ratio correction
PHOTO lamp
SPF mode scan direction magnification ratio correction
AE, TEXT, PHOTO lamps