AR-122E (serv.man9). Sect 10. Simulation Trouble Codes - Sharp Copying Equipment Service Manual (repair manual). Page 8

Read Sharp AR-122E (serv.man9) Service Manual online

AR-122E/152E/153E/157E  SIMULATION, TROUBLE CODES  10 - 8
26
43
Side void setup
(Operation/Procedure)
1. When this simulation is executed, the currently set code number of the side void amount is displayed.
2. Enter the code number and press the start key. The setting is changed.
44
SPF document rear edge read setup + Fax document rear edge scan setup.
When this simulation is executed, the currently set code number is displayed. Enter the desired code number and press the START 
key, and the display will be changed. The document rear edge scanning area in SPF reduction (less than 100%) copy is changed.
The code number is changeable in the range of 0 – 8.
The default value is 4, and 2 mm of the document rear edge is cut.
When the value is changed by 1, the area is changed by 1 mm.
62
Energy-save mode copy lamp setup
Used to set half-ON (50%)/OFF of the copy lamp in the pre-heat mode.
When this simulation is executed, the current setup of the code number is displayed. Enter the code number and press the PRINT 
switch to enable the setup.
63
Fan control select setup
Used to set the cooling fan operation mode.
When this simulation is executed, the current setup of the code number is displayed. Enter the code number and press the PRINT 
switch to enable the setup.
64
Heater control setup during the scanner mode
When this simulation is executed, the currently set code number of heater control setup is displayed. Enter a desired code number of 
heater control setup and press the PRINT switch, and the new setup is enabled.
30
01
Paper sensor status display
Indicates the paper sensor status using the lamps on the operation panel. 
Main 
code
Sub 
code
Content
Code number
Setting
0
0  mm
1
0.5 mm
2
1.0 mm
3
1.5 mm
4
2.0 mm * Default
5
2.5 mm
6
3.0 mm
7
3.5 mm
8
4.0 mm
9
4.5 mm
10
5.0 mm
Code number
Setup
0
Copy lamp half-ON (50%) * Default
1
Copy lamp OFF
Code number
Setup
1
1-speed fan control
2
2-speed fan control * Default when starting mass production
 Code number
Heater control setup
 0
Heater control ON
* Default (Except for Europe)
1
Heater control OFF
* Default (For Europe only)
Sensor name
Display lamp
Before-resist paper sensor (PPD1)
Developer cartridge replacement lamp
Fusing section paper sensor (PPD2)
JAM lamp
Paper exit sensor (POD)
Photoconductor cartridge replacement lamp
2nd CS paper sensor (PPD3)
2nd cassette lamp
New drum cartridge sensor (PUIS)
Zoom lamp
Single manual feed paper sensor (MFD)
AE lamp