AM-400 (serv.man8). Chapter 2 (Adjustments). - Sharp Copying Equipment Service Manual (repair manual). Page 28

Read Sharp AM-400 (serv.man8) Service Manual online

AM-400DE
2 – 28
SW16 No. 4 Reserved (AM-400DE/IT)
Set to "1".
SW16 No. 4 Reserved (AM-400F/SE/H)
Set to "0".
SW16 No. 5, No. 6 Reserved
Set to "0".
SW16 No. 7 Reserved (AM-400DE/IT/SE/H)
Set to "0".
SW16 No. 7 Reserved (AM-400F)
Set to "1".
SW16 No. 8 Reserved
Set to "0".
SW17 No. 1, No. 2 Delay timer before line connect in auto dial
Set a time period between start of dial operation and line connection in
the auto dial mode.
SW17 No. 3, No. 4 Delay timer after line connect in auto dial
Set a time period between dial-up line connection and dial data trans-
mission in the auto dial mode.
SW17 No. 5, No. 6 Calling time
Set the call time for dialing in the auto dial mode.
SW17 No. 7, No. 8 CNG timing
Set a time period between dialing in the auto dial mode and CNG sig-
nal transmission.
SW18 No. 1 Key push sound
Used to toggle the key sound between on and off.
SW18 No. 2 Line monitor type
The time period to monitor the sound on the line is set.
0: From the start of dialing, and until the call reaches receiving party
1: From the start of dialing to the end of the communication
SW18 No. 3 Pause time
The dial pause time is set.
SW18 No. 4 Ringing display (if ringer volume is OFF)
When set to “1” and ringer volume is OFF, “RINGING” display informs
you that the CI signals are received.
SW18 No. 5 Dial tone detection (before auto dial)
When set to “1”, a number is dialed after detecting the dial tone.
SW18 No. 6 Busy tone detection (after auto dial)
When set to “1”, the busy tone is detected after dialing a number.
SW18 No. 7 Reserved
Set to "0".
SW18 No. 8 Line monitor
When set to “1”, sound on the line is monitored in transmission.
SW19 No.1 ~ No. 4 CI signal frequency
Used to set a frequency that is considered as the CI signal.
SW19 No. 5 ~ No. 7 CI signal OFF detect enable time
Used to set the maximum length of CI signal OFF time, which is used
to determine a sequence of CI signals.
SW19 No. 8 Method of detecting CI frequency
CI frequency detection method is set.
SW20 No. 1 Pulse format of D.P.
Used to set pulse format of D.P. mode.
SW20 No. 2 ~ No. 4 Inter digit pause time
Used to set the pause time between pulses
SW20 No. 5 Pulse Make/Break ratio.
Used to set pulse ratio of D.P. mode.
SW20 No. 6 The change to DB from DP by (
)
When setting to 1, the mode is changed by pressing the 
 key from
the pulse dial mode to the tone dial mode.
SW20 No. 7, No. 8 Reserved
Set to "0".
SW21 No. 1 Reserved
Set to "1".
SW21 No. 2 DTMF sending by panel test mode
With this switch set to “1”, the DTMF signal is sent when a numeric key
is pressed in the panel test mode.
SW21 No. 3, No. 4 Busy tone detection pulse number
Used to set detection of Busy tone intermittent sounds.
SW21 No. 5 Reserved
Set to "0".
SW21 No. 6 Reserved
Set to "1".
SW21 No. 7 Reserved
Set to "0".
SW21 No. 8 Reserved
Set to "1".
SW22 No. 1 Print mode when printer life over
Used to set whether the printing operation stops or not when the
PRINTER LIFE OVER error occurs. 
SW22 No. 2 Print mode when drum life over
Used to set whether the printing operation stops or not when the
DRUM LIFE OVER error occurs. 
SW22 No. 3 Print mode when toner empty
Used to set whether the printing operation stops or not when the
TONER EMPTY error occurs. 
SW22 No. 4 Print mode when toner unsuitable
Used to set whether the printing operation stops or not when the
TONER UNSUITABLE error occurs. 
SW22 No. 5 Print mode when size error
Used to set whether the printing operation stops or not when the SIZE
ERROR occurs. 
SW22 No. 6 Print mode when paper tray removed
Used to set whether the printing operation stops or not when the
PAPER TRAY REMOVED error occurs. 
SW22 No. 7, No. 8 Reserved
Set to "1".
SW23 No. 1 ~ No. 4 Paper size at tray
The paper size in the tray is set.
SW23 No. 5, No. 6 Fan time after printing
Set the FAN rotation time for completed print operation.
Page of 31
Display