Read Sharp AM-400 (serv.man8) Service Manual online
AM-400DE
2 – 28
SW16 No. 4 Reserved (AM-400DE/IT)
Set to "1".
SW16 No. 4 Reserved (AM-400F/SE/H)
Set to "0".
SW16 No. 5, No. 6 Reserved
Set to "0".
SW16 No. 7 Reserved (AM-400DE/IT/SE/H)
Set to "0".
SW16 No. 7 Reserved (AM-400F)
Set to "1".
SW16 No. 8 Reserved
Set to "0".
SW17 No. 1, No. 2 Delay timer before line connect in auto dial
Set a time period between start of dial operation and line connection in
the auto dial mode.
the auto dial mode.
SW17 No. 3, No. 4 Delay timer after line connect in auto dial
Set a time period between dial-up line connection and dial data trans-
mission in the auto dial mode.
mission in the auto dial mode.
SW17 No. 5, No. 6 Calling time
Set the call time for dialing in the auto dial mode.
SW17 No. 7, No. 8 CNG timing
Set a time period between dialing in the auto dial mode and CNG sig-
nal transmission.
nal transmission.
SW18 No. 1 Key push sound
Used to toggle the key sound between on and off.
SW18 No. 2 Line monitor type
The time period to monitor the sound on the line is set.
0: From the start of dialing, and until the call reaches receiving party
1: From the start of dialing to the end of the communication
SW18 No. 3 Pause time
The dial pause time is set.
SW18 No. 4 Ringing display (if ringer volume is OFF)
When set to “1” and ringer volume is OFF, “RINGING” display informs
you that the CI signals are received.
you that the CI signals are received.
SW18 No. 5 Dial tone detection (before auto dial)
When set to “1”, a number is dialed after detecting the dial tone.
SW18 No. 6 Busy tone detection (after auto dial)
When set to “1”, the busy tone is detected after dialing a number.
SW18 No. 7 Reserved
Set to "0".
SW18 No. 8 Line monitor
When set to “1”, sound on the line is monitored in transmission.
SW19 No.1 ~ No. 4 CI signal frequency
Used to set a frequency that is considered as the CI signal.
SW19 No. 5 ~ No. 7 CI signal OFF detect enable time
Used to set the maximum length of CI signal OFF time, which is used
to determine a sequence of CI signals.
to determine a sequence of CI signals.
SW19 No. 8 Method of detecting CI frequency
CI frequency detection method is set.
SW20 No. 1 Pulse format of D.P.
Used to set pulse format of D.P. mode.
SW20 No. 2 ~ No. 4 Inter digit pause time
Used to set the pause time between pulses
SW20 No. 5 Pulse Make/Break ratio.
Used to set pulse ratio of D.P. mode.
SW20 No. 6 The change to DB from DP by (
)
When setting to 1, the mode is changed by pressing the
key from
the pulse dial mode to the tone dial mode.
SW20 No. 7, No. 8 Reserved
Set to "0".
SW21 No. 1 Reserved
Set to "1".
SW21 No. 2 DTMF sending by panel test mode
With this switch set to “1”, the DTMF signal is sent when a numeric key
is pressed in the panel test mode.
is pressed in the panel test mode.
SW21 No. 3, No. 4 Busy tone detection pulse number
Used to set detection of Busy tone intermittent sounds.
SW21 No. 5 Reserved
Set to "0".
SW21 No. 6 Reserved
Set to "1".
SW21 No. 7 Reserved
Set to "0".
SW21 No. 8 Reserved
Set to "1".
SW22 No. 1 Print mode when printer life over
Used to set whether the printing operation stops or not when the
PRINTER LIFE OVER error occurs.
PRINTER LIFE OVER error occurs.
SW22 No. 2 Print mode when drum life over
Used to set whether the printing operation stops or not when the
DRUM LIFE OVER error occurs.
DRUM LIFE OVER error occurs.
SW22 No. 3 Print mode when toner empty
Used to set whether the printing operation stops or not when the
TONER EMPTY error occurs.
TONER EMPTY error occurs.
SW22 No. 4 Print mode when toner unsuitable
Used to set whether the printing operation stops or not when the
TONER UNSUITABLE error occurs.
TONER UNSUITABLE error occurs.
SW22 No. 5 Print mode when size error
Used to set whether the printing operation stops or not when the SIZE
ERROR occurs.
ERROR occurs.
SW22 No. 6 Print mode when paper tray removed
Used to set whether the printing operation stops or not when the
PAPER TRAY REMOVED error occurs.
PAPER TRAY REMOVED error occurs.
SW22 No. 7, No. 8 Reserved
Set to "1".
SW23 No. 1 ~ No. 4 Paper size at tray
The paper size in the tray is set.
SW23 No. 5, No. 6 Fan time after printing
Set the FAN rotation time for completed print operation.
Click on the first or last page to see other AM-400 (serv.man8) service manuals if exist.