CHAPTER 6. FIRMWARE UPDATA PROCEDURES/EDID WRITING PROCEDURES
PN-E601 FIRMWARE UPDATA PROCEDURES/EDID WRITING PROCEDURES
 6 – 2
1 - 2. FIRMWARE UPDATE
1 ) Press [Main Firmware] button of the Service Tool Launcher.
The library (CGProbe5.3.0.1.dll) is registered, and the updater starts up.
2 ) Select the COM port to be used for communication. 
(“COM1” on the above screen)
3 ) Set the batch file name as “C:./isp_flash16_ext.txt”. 
(It is set as the default. Do not change it.)
4 ) Press [BATCH] button, and the firmware writing is started. 
For about 3 minutes and writing is completed. When “Firmware
version up completed” is displayed, the firmware update is com-
pleted.
MEMO
n
Very occasionally it takes about 8 minutes to write the firmware
on Windows Vista
5 )
The new version firmware can be operated by turning OFF and ON
the main power.
6 ) When [BATCH] button is pressed with the other model connected,
the following “ERROR !!! “Wrong Model Type”” message is dis-
played. Check to confirm the connected model of information mon-
itor.
■ WHEN UPDATING IS FAILED
First, turn OFF the main power and then turn it ON again. Then, press
[BATCH2] button to start writing the firmware. (Don’t press [BATCH3].)
In about 4 minutes, updating is completed and “Firmware update com-
pleted” is displayed. It is the end of firmware updating. 
MEMO
n
Very occasionally it takes about 8 minutes to write the firmware
on Windows Vista. 
After completion of firmware updating, turn OFF and ON the main
power, and the new version firmware is operated. 