n
Response code format
When a command has been executed correctly
Return code
(0D
H
, 0A
H
)
A response is returned after a command is executed.
*  If an ID number has been assigned
K  SPC  0 
ID number of responding monitor 
Space (20
H
Return code
(0D
H
, 0A
H
)
When a command has not been executed
Return code
(0D
H
, 0A
H
)
*  If an ID number has been assigned
SPC  0 
ID number 
Space (20
H
Return code
(0D
H
, 0A
H
)
TIPS
•  “ERR” is returned when there is no relevant command or 
when the command cannot be used in the current state of 
the monitor.
•   If communication has not been established for reasons 
such as a bad connection between the PC and monitor, 
nothing is returned (not even ERR).
•   If no monitor has been assigned the designated ID number 
(e.g. if the command IDSL0002   is used, but no monitor 
with ID number: 2 is found), no response is returned.
•   If RS-232C/LAN COMMAND is set to options other than 
NORMAL, the return code for a response is 0D
H
 only.
If execution of the command is taking some time
Return code
(0D
H
, 0A
H
)
When the following commands are used, “WAIT” is returned. 
In this case, a value will be returned if you wait a while. Do not 
send any command during this period.
No ID number is attached to WAIT response.
•  Commands which return WAIT:
1.  When repeater control is used
2.  When an IDSL or IDLK command is used
3.  When one of the following commands is used: RSET, 
INPS, ASNC, WIDE, EMAG, EPOS, PXSL, POWR, 
AGIN, MWIN, MWIP, MWPP, ESTG, EMHV, EPHV, 
ESHV
When control via RS-232C is locked (to prevent use) 
using the operation lock function (see page 11)
Return code
(0D
H
, 0A
H
)
When RS-232C/LAN SELECT is set to LAN
U  N  S  E  L  E  C  T  E  D 
Return code
(0D
H
, 0A
H
)
n
Communication interval
•  After OK or ERR is returned, you must send the following 
commands.
  To set a timeout for the command response, specify 10 
seconds or longer.
•  Provide an interval of 100 ms or more between the 
command response and the transmission of the next 
command.
VOLM0020 
OK 
 
 
INPS0001 
WAIT 
OK 
Interval of 100 ms or more
TIPS
•  When executing ALL RESET, set the timeout period to 30 
seconds or longer. 
•  When turning the power on while the POWER ON DELAY 
function is in use, set the timeout period to the POWER ON 
DELAY period + 10 seconds or longer.
Advanced operation
This section explains commands for daisy chain connection. 
The basic communication procedure is the same as in the 
“One-to-one connection with a PC” section.
n
ID numbers
You can assign a unique ID number to each monitor (see 
page 7). This allows you to control a particular monitor in a 
daisy chain of monitors.
You can assign ID numbers either from the menu screen (using 
the remote control) or from the PC using RS-232 cable.
[Example] 
ID number: 1  ID number: 2  ID number: 3  ID number: 4
If monitors are connected as shown above, you can 
execute commands like “Set the volume of the monitor with 
ID 4 to 20”.
When controlling monitors linked in a daisy chain by 
designating ID numbers, you should basically avoid any 
duplication of ID numbers.
ID numbers do not have to be assigned in ascending order 
starting from the PC. They can also be connected as shown 
below.
[Example] 
ID number: 3  ID number: 2  ID number: 4  ID number: 1
Page of 30