PN-S655 (serv.man5) - Sharp Monitor User Guide / Operation Manual. Page 11

Read Sharp PN-S655 (serv.man5) User Guide / Operation Manual online

11
E
You can return the settings to their factory-preset values and 
restrict operations.
1.  After pressing 
SIZE
 for about 5 seconds, press 
 , 
 , 
 , and 
 in that order.
OFF 
UNLOCKED 
ON 
ON 
LED 
OFF 
FUNCTION 
1/1 
ALL RESET 
ADJUSTMENT LOCK 
RS-232C/LAN 
OSD DISPLAY 
LED 
TEMPERATURE ALERT 
STATUS ALERT 
END…[MENU]
2.  Select and set the items.
ALL RESET
Resets the settings to the factory default settings.  
Press 
 , select the resetting method, and then press 
MENU
.
After initialization, turn the main power switch off and 
then back on.
ALL RESET1 ....Resets all the settings to the factory 
default settings.
ALL RESET2 ....Returns all settings to the factory default 
settings except for the following items: 
LAN SETUP, RS-232C/LAN SELECT, 
NETWORK, MAIL, and SERVICE & 
SUPPORT (See page 7, and pages 25 
to 28.)
ADJUSTMENT LOCK
You can disable operations on the monitor and the 
remote control unit that use buttons.
OFF ...Enables operation.
1.........Disables all operations other than turning power 
on/off and FUNCTION.
2.........Only the FUNCTION operation is enabled. 
Disables all operations other than FUNCTION (not 
even power on/off).
RS-232C/LAN
Specifies whether to allow control via RS-232C or LAN 
(see pages 12 and 21).
OSD DISPLAY
Hides/shows menus. 
The FUNCTION screen cannot be hidden.
LED
Specifies whether to light power LEDs.
Initialization (Reset)/Functional Restriction Setting
TEMPERATURE ALERT
Selects the notification method for an abnormal 
temperature.
OFF .............. Do not notify about an abnormal 
temperature.
OSD & LED .. When an abnormal temperature is 
detected, the power LED flashes in red 
and green alternately and the screen 
displays a message: TEMPERATURE.
LED............... When an abnormal temperature is 
detected, the power LED flashes in red 
and green alternately.
STATUS ALERT
Selects the notification method for a hardware error.
OFF .............. Do not notify about the error.
OSD & LED .. When a hardware error is detected, the 
power LED flashes in red and the screen 
displays a message: STATUS [xxxx].
LED............... When a hardware error is detected, the 
power LED flashes in red.
3.  Press 
MENU
 to return to the normal screen.
TIPS
•  When both abnormal temperature and hardware error are 
detected, the hardware error notification overrides.
Page of 30
Display

Click on the first or last page to see other PN-S655 (serv.man5) service manuals if exist.