PN-S655 (serv.man5) - Sharp Monitor User Guide / Operation Manual. Page 12

Read Sharp PN-S655 (serv.man5) User Guide / Operation Manual online

12
E
Controlling the Monitor with a PC (RS-232C)
You can control this monitor from a PC via RS-232C (COM 
port) on the PC.
You can also connect multiple monitors via a daisy chain by 
using a PC. By assigning ID numbers to each monitor (see 
page 13), you can make input mode selection/adjustment or 
can check the status of a specific monitor.
Caution
•  To control the monitor via RS-232C, set RS-232C/LAN 
SELECT to RS-232C.
•  You cannot use RS-232C and LAN control simultaneously.
PC connection
n
One-to-one connection with a PC
Connect with RS-232 straight cable between the PC’s COM 
port (RS-232C connector) and the RS-232C input terminal on 
the monitor.
RS-232 straight cable  
(commercially available) 
To COM port 
PC 
RS-232C input terminal
n
Daisy chain connection…
Advanced operation
Connect with RS-232 straight cable between the PC’s COM 
port (RS-232C connector) and the RS-232C input terminal on 
the first monitor. 
Next, connect RS-232 straight cable to the first monitor’s 
RS-232C output terminal and to the second monitor’s 
RS-232C input terminal. Connect in the same way to the third 
and subsequent monitors.
Up to 25 monitors can be connected. (Depending on the 
length of the cable used and the surrounding environment.)
RS-232 straight cables  
(commercially available) 
First monitor 
Second monitor 
PC 
To COM port 
RS-232C  
output terminal 
RS-232C 
input terminal
Communication conditions
Set the RS-232C communication settings on the PC to match 
the monitor’s communication settings as follows:
Baud rate
9600 bps
Stop bit
1 bit
Data length
8 bits
Flow control
None
Parity bit
None
Communication procedure
n
Command format
When a command is sent from the PC to the monitor, the 
monitor operates according to the received command and 
sends a response message to the PC.
C1  C2  C3  C4  P1  P2  P3  P4 
Return code 
Command field  
(4 prescribed  
alphanumerical characters) 
Parameter field 
(4 character string comprised of: 
0-9, +, -, space, ?)
 Example:  VOLM0030
 
VOLM     30
*  Be sure to input 4 characters for the parameter. Pad with 
spaces (“ ”) if necessary.  
(“   ” is a return code (0D
H
, 0A
H
 or 0D
H
))
Wrong  : VOLM30
Right  : VOLM     30
When inputting a negative value, specify a numerical value in 
three digits.
 Example: AUTR-009
Do not use spaces for MPOS, DATE, and SC01 through 
SC08. Specify parameters using a specified number of 
characters.
 Example: MPOS010097
If a command has “R” listed for “DIRECTION” in the 
“RS-232C command table” on page 16, the current value can 
be returned by using “?” as the parameter.
 Example:
VOLM ? ? ? ?
From PC to monitor (How much 
is current volume setting?).
30
From monitor to PC (Current 
volume setting: 30).
*  If an ID number (see page 13) has been assigned 
(For example, ID number = 1).
VOLM 
?
From PC to monitor.
30   001
From monitor to PC.
Page of 30
Display

Click on the first or last page to see other PN-S655 (serv.man5) service manuals if exist.