PN-R603 (serv.man7) - Sharp Monitor User Guide / Operation Manual. Page 36

Read Sharp PN-R603 (serv.man7) User Guide / Operation Manual online

36
E
Controlling the Monitor with a PC (RS-232C)
n
Repeater control
This system has a function to allow setting of multiple 
monitors connected in a daisy chain using a single command. 
This function is called repeater control. You can use Repeater 
control function without assigning ID numbers.
[Example] 
Set 1 
 
Set 2 
Set 3
Set 4
*   If monitors are connected as shown above, you can 
execute a command like “Set all monitors’ input settings to 
D-SUB[RGB]”.
n
Repeater control command
Repeater control is achieved by setting the FOURTH 
CHARACTER of the parameter to “+”.
Example:
VOLM030 +
Sets volume of all monitors to 30.
In repeater control, responses are returned by all the 
connected monitors.
If you want to determine that a value has been returned by a 
specific set, assign ID numbers to each monitor in advance.
When some monitors do not return their responses, the 
probable cause is that the monitors could not receive the 
command or command processing is not complete. Do not 
send a new command.
Example:  (When 4 monitors are connected, and 
assigned ID numbers: 1 through 4)
VOLM030 +
WAIT
OK   001
OK   002
OK   003
OK   004
← If 4 monitors are connected in 
a chain, reliable operation can 
be ensured by sending a new 
command only after a reply 
has been returned by 4th (last) 
monitor.
Repeater control can also be used for reading settings.
Example:
VOLM ? ? ? +
WAIT
10   001
Volume settings for all 
monitors are returned.
20   002
30   003
30   004
TIPS
•  If repeater control is used during ID designation (IDSL, 
IDLK), the ID designation is canceled.
Setting of the GAMMA user data
n
To transfer the GAMMA user data
Use the user data transfer commands (UGRW, UGGW and 
UGBW). For each of the R, G and B colors, divide the total 
512 pieces of user data into 16 blocks, and transfer 32 pieces 
of data with each command.
C1 C2 C3 C4 P1 P2 P3 P4
… S1 S2
Command field Block number (01 to 16) Data field Checksum field
  Example: To transfer the data of block 1 (0 to 31 levels) 
of red (R) data
UGRW01000000010002 … 0031C0
Command Block number 32 pieces of data
Checksum
One piece of data consists
of 4 digits.
*  If data is less than 4 digits, add a “0” (zero) to make it 4 
digits.
*  The checksum field is the character string (ASCII) data of 
lower-order one byte which indicates the sum of the block 
number and 32 pieces of data in hexadecimal (0 to F).
n
Saving the GAMMA user data
Use the user data save command (UGSV) to save the 
transferred user data in the monitor.
If the data is not saved, it will be cleared when:
•  The main power switch is off
•  STANDBY MODE is LOW POWER and the monitor enters 
standby mode
n
Activating the GAMMA user data
To activate the transferred user data, select USER for GAMMA 
of the PICTURE menu, or send the corresponding RS-232C 
command.
n
Checking the GAMMA user data
Use the user data read commands (UGRR, UGGR and 
UGBR) to return 512 pieces of user data for each of the R, 
G and B colors. Divide the data into 16 blocks and return 32 
pieces of data with each command. The value to be returned 
is not the value stored in the monitor, but the value in the 
temporary memory for display. (These values are the same 
when the user data save command (UGSV) above has been 
sent.)
TIPS
•  The user data is not initialized by RESET of the PICTURE 
menu. To initialize the user data, use ALL RESET of the 
FUNCTION menu. 
The GAMMA user data initialize command (UGRS) allows 
the initialization of the user data only.
Page of 63