Controlling the Monitor with a PC (RS-232C)
n
Commands for ID control
The command examples shown on this page assume the 
following connection and ID number set up.
ID number: 1  ID number: 2  ID number: 3 ID number: 4
IDST ......... A monitor receiving this command sets its own ID 
number in the parameter field.
 Example:
IDST0001
OK   001 ←
The ID number of this monitor is set to 1.
TIPS
You can automatically assign ID numbers by using the IDST 
command with the Repeater control (see “Repeater control” 
on page 36).
For example, using the command “IDST001+” automatically 
sets the ID numbers, as shown below.
[Example] 
ID number: 1  ID number: 2  ID number: 3 ID number: 4
IDST001 +
ID setting command with repeater control
WAIT
OK   001
“OK” response from ID number: 1
OK   002
“OK” response from ID number: 2
OK   003
“OK” response from ID number: 3
OK   004
“OK” response from ID number: 4 (End)
IDSL ........The parameter of this command sets the ID number 
of the monitor. The monitor is subject to the next 
command.
 Example: 
IDSL0002
The next command is for the monitor 
with ID number: 2.
WAIT
Searching for monitor with ID number: 
2
OK   002
Found monitor with ID number: 2
VOLM0030
Sets volume of monitor with ID 
number: 2 to 30.
WAIT
Processing
OK   002
OK response from monitor with ID 
number: 2
VOLM0020
Sets volume to 20.
OK   001
The volume of the monitor with ID 
number: 1 (the one directly connected 
to the PC) is set to 20.*
*   The IDSL command is effective only once, for the 
immediately succeeding command.
IDLK ........The parameter of this command sets the ID 
number of the monitor. The monitor is subject to all 
subsequent commands.
 Example: 
IDLK0002
Following commands are for the monitor 
with ID number: 2.
WAIT
Searching for monitor with ID number: 
2
OK   002
Found monitor with ID number: 2
VOLM0030
Sets volume of monitor with ID 
number: 2 to 30.*
WAIT
Processing
OK   002
VOLM0020
Sets volume of monitor with ID 
number: 2 to 20.*
WAIT
OK   002
IDLK0000
Canceling fixed ID number setting
WAIT
Canceling IDLK
OK   002
Cancelation complete
VOLM0010
OK   001
The volume of the monitor with ID number: 
1 (the one directly connected to the PC) is 
set to 10. (IDLK is canceled.)
*   The IDLK command remains effective until it is 
canceled, or power is shut off.
IDCK ........Provides screen display of the ID number currently 
assigned to a monitor, and the ID number currently 
set for IDLK (if any).
 Example:
(After executing IDLK0002)
IDCK0000
(Parameter has no meaning.)
ID : 001    IDLK : 002
Returned response. The ID 
number is also displayed on the 
monitor screen.
IDCK000 + 
Repeater control. (If a command 
is used with repeater control, ID 
designation using IDSL or IDLK 
is canceled.)
WAIT
ID : 001    IDLK : 000
ID : 002    IDLK : 000
ID : 003    IDLK : 000
ID : 004    IDLK : 000
Page of 63