32
E
You can return the settings to their factory-preset values and 
restrict operations.
1.  Hold 
SIZE
 down until “F” appears in the upper left 
corner of the screen.
2.  While “F” appears, press  
 , 
 , 
 , 
 in that 
order.
 
OFF
UNLOCKED
ON 1
ON
LED
OFF
MONITOR
FUNCTION
ALL RESET
ADJUSTMENT LOCK
ADJUSTMENT LOCK TARGET
RS-232C/LAN
OSD DISPLAY
LED
TEMPERATURE ALERT
STATUS ALERT
POWER BUTTON
CONTROLLER INPUT
  OK…[ENTER]  END…[RETURN]
3.  Select and set the items.
ALL RESET
Resets the settings to the factory default settings.  
Press 
ENTER
 , select the resetting method, and then press 
ENTER
.
After initialization, turn the main power switch off and 
then back on.
ALL RESET1 ....Resets all the settings to the factory 
default settings.
ALL RESET2 ....Returns all settings to the factory default 
settings except for the following items: 
LAN SETUP, RS-232C/LAN SELECT, 
ID No. SET, BAUD RATE, NETWORK, 
MAIL, SERVICE & SUPPORT, and 
SNMP (See page 25, and pages 49 to 
52.)
ADJUSTMENT LOCK
You can disable operations on the monitor and the 
remote control unit that use buttons.
OFF ...Enables operation.
ON 1 ..Disables all operations other than turning power 
on/off and FUNCTION.
ON 2 ..Only the FUNCTION operation is enabled. 
Disables all operations other than FUNCTION (not 
even power on/off).
ADJUSTMENT LOCK TARGET
Sets the target to prohibit operation of with 
ADJUSTMENT LOCK.
REMOTE CONTROL ..... Prohibits remote control 
operation
MONITOR BUTTONS ... Prohibits monitor switch 
operation
BOTH ............................. Prohibits remote control and 
monitor switch operation
RS-232C/LAN
Specifies whether to allow control via RS-232C or LAN 
(see pages 33 and 45).
Initialization (Reset)/Functional Restriction Setting (FUNCTION)
OSD DISPLAY
Shows/hides the menu, modes and messages.
The FUNCTION screen cannot be hidden.
ON 1 .............. Shows all menus, modes and messages.
ON 2 .............. Hides messages automatically displayed 
by the display. Shows messages during 
operation.
OFF ............... Hides all menus, modes and messages.
LED
Specifies whether to light the power LED.
TEMPERATURE ALERT
Selects the notification method for an abnormal 
temperature.
OFF .............. Do not notify about an abnormal 
temperature.
OSD & LED .. When an abnormal temperature is 
detected, the power LED flashes in red 
and green alternately and the screen 
displays a message: TEMPERATURE.
LED............... When an abnormal temperature is 
detected, the power LED flashes in red 
and green alternately.
STATUS ALERT
Selects the notification method for a hardware error.
OFF .............. Do not notify about the error.
OSD & LED .. When a hardware error is detected, the 
power LED flashes in red and the screen 
displays a message: STATUS [xxxx].
LED............... When a hardware error is detected, the 
power LED flashes in red.
POWER BUTTON
Normally, leave this setting as MONITOR.
When using an optional part, if instruction appears, 
change the setting accordingly.
CONTROLLER INPUT
Normally, you do not need to change this setting.
When using an optional part, if instruction appears, 
change the setting accordingly.
4.  Press 
RETURN
 to return to the normal screen.
TIPS
•  When both abnormal temperature and hardware error are 
detected, the hardware error notification overrides.
•  If TEMPERATURE ALERT or STATUS ALERT is set to 
OSD&LED, alert messages will appear even if the OSD 
DISPLAY is set to ON 2 or OFF.
•  If TEMPERATURE ALERT or STATUS ALERT is set to LED 
or OSD & LED, the LED lights even if the LED function is 
set to OFF.
Page of 63