CHAPTER 2. INSTALLATION, ADJUSTMENT, SETTING
PN-E601 INSTALLATION, ADJUSTMENT, SETTING
2 – 5
<DAISY CHAIN CONNECTION [ADVANCED OPERATION]>
Connect with RS-232 straight cable between the PC's COM port (RS-
232C connector) and the RS-232C input terminal on the first monitor.
232C connector) and the RS-232C input terminal on the first monitor.
Next, connect RS-232 straight cable to the first monitor's RS-232C out-
put terminal and to the second monitor's RS-232C input terminal. Con-
nect in the same way to the third and subsequent monitors.
Up to 25 monitors can be connected. (Depending on the length of the
cable used and the surrounding environment.)
cable used and the surrounding environment.)
<COMMUNICATION CONDITIONS>
Set the RS-232C communication settings on the PC to match the moni-
tor's communication settings as follows.
tor's communication settings as follows.
*
1
Set to the same baud rate as the “BAUD RATE” setting of
SETUP menu.
SETUP menu.
When connecting multiple monitors in a daisy chain, set all mon-
itors to the same “BAUD RATE”.
■ CONTROLLING THE MONITOR WITH A PC
(LAN)
When the PN-ZB01 (optionel) is a attached, your monitor can be con-
nected to a LAN allowing you to control it from a PC on the LAN.
You can also configure the monitor to send e-mail notification when it
has a problem.
has a problem.
The connection requires a commercially available LAN cable (UTP
cable, Category 5, straight through).
MEMO
n
3Refer to page 3 - 18 "2 - 1. SETTING TO CONNECT TO A
LAN".
n
Your PC must be installed with Internet Explorer (version 6.0 or
later).
n
To control the monitor via LAN, set RS-232C/LAN SELECT to
LAN.
LAN.
n
You cannot use RS-232C and LAN control simultaneously.
CAUTION
INITIALIZING PERSONAL INFORMATION
n
When the PN-ZB01 (optional) is attached, personal information
such as e-mail addresses can be registered in the monitor.
Before transferring or disposing of the monitor, initialize all set-
tings by selecting “ALL RESET1”. Note that “ALL RESET2” will
tings by selecting “ALL RESET1”. Note that “ALL RESET2” will
not initialize e-mail addresses and other settings.
Baud rate
9600 bps (Initial setting)
*1
Data length
8 bits
Parity bit
None
Stop bit
1 bit
Flow control
None
RS-232 straight cables
(commercially available)
(commercially available)
First monitor
Second monitor
PC
To COM port
RS-232C
output terminal
output terminal
RS-232C
input terminal
input terminal
Hub
LAN terminal
LAN cable (commercially available, straight)