5. Pull out the oven lamp socket.
6. Remove the oven lamp from the oven lamp socket.
7. Now, the oven lamp socket is free.
Figure C-1. Oven lamp socket
1. Open covers of the terminal insulator by using small flat type
screw driver.
2. Remove the receptacle from the terminal insulator.
3. Now, the terminal insulator is free.
TERMINAL INSULATOR REPLACEMENT
Installation
1. Insert the receptacle into terminal insulator.
2. Close covers of the terminal insulator, as shown illustrated
below
1. CARRY OUT 3D CHECKS.
2. Push the lever of positive lock® connector.
3. Pull down on the positive lock® connector.
CAUTION: WHEN CONNECTING THE POSITIVE LOCK®
CONNECTORS TO THE TERMINALS, CONNECT
THE POSITIVE LOCK® SO THAT THE LEVER
FACES YOU.
POSITIVE LOCK® CONNECTOR (NO-CASE TYPE) REMOVAL
Figure C-3. Positive lock® connector
R
emoval
1. CARRY OUT 3D CHECKS.
2. Remove the one (1) screw holding the green/ yellow wire
of the power supply cord to the bottom plate.
3. Disconnect the blue and brown wire leads of the power
supply cord from the noise filter.
4. Nip the cord bushing with bushing pliers and release it
from the hole of the back plate.
5. Remove the cord bushing from the power supply cord,
and the power supply cord from the back plate.
6. Now, the power supply cord is free.
Reinstall
1. Reinstall the cord bushing to the power supply cord.
2. Insert the power supply cord with the cord bushing into the
hole of the back plate.
3. Hold the green/ yellow wire of the power supply cord to the
bottom plate with the one (1) screw.
4. Reconnect the blue and brown wire leads of the power
supply cord to noise filter, referring to the pictorial diagram.
POWER SUPPLY CORD REPLACEMENT
5. Not to be caught by the outer case cabinet, pass the
green/ yellow wire of the power supply cord under the high
voltage capacitor.
6. Reinstall the outer case cabinet and check that the oven
is operating properly.
Figure C-4. Power supply cord replacement
Flat type
screw driver
Terminal 
insulator
Receptacle
Covers
N
L
Back plate
Bottom plate
Power supply cord
Blue wire
Cord bushing
High voltage
capacitor
Brown wire
Green/ Yellow
wire
Noise filter
Screw
Terminal
Push
Pull down
1
2
Lever
Positive lock®
connector
Figure C-2(a). Terminal insulator
Figure C-2(b). Terminal insulator
BACK PLATE REMOVAL
1. CARRY OUT 3D CHECKS.
2. Remove the one (1) screw holding the green/ yellow wire
of the power supply cord to the bottom plate.
3. Disconnect the blue and brown wire leads wire of the
power supply cord from the noise filter.
4. Remove the three (3) screws holding the back plate to the
bottom plate.
5. Remove the two (2) screws holding the back plate to the
exhaust duct.
6. Remove the two (2) screws holding the right and left
chassis supports to the back plate.
7. Release the tabs of the chassis supports from the back
plate.
8. Now, the back plate with the power supply cord is free.
Oven lamp
socket
Terminal
Wire lead
Terminal hole
Flat type small
screw driver
Page of 44