R-795M (serv.man9). Component replacement and adjustment procedure - Sharp Home Appliance Service Manual (repair manual). Page 6

Read Sharp R-795M (serv.man9) Service Manual online

R-795M
 - 
28
Pin
PIN
Lower
Oven Hinge
Upper
Oven Hinge
Lower
Oven 
Hinge
Choke Cover
Slit Choke
Door Panel
Door Sub 
Assembly
COMPONENT REPLACEMENT AND ADJUSTMENT PROCEDURE
Choke Cover
Putty Knife
Door Frame
Figure C-7. Door Disassembly
REMOVAL
1. Disconnect the oven from the power supply.
2. Pull open the door slightly.
3. Insert a putty knife (thickness of about 0.5mm) into the
gap between the choke cover and door frame as shown
in Figure C-7 to free engaging parts.
4. Release choke cover  from door panel.
5. Now choke cover is free.
NOTE: When carrying out any repair to the door, do
not bend or warp the slit choke (tabs on the
door panel assembly) to prevent microwave
leakage.
Figure C-7. Door Disassembly
6. Lift the door upwards.
7. Now, door sub assembly is free from oven cavity.
8. Remove the four (4) screws holding the door panel to
the door frame.
9. Now, door panel is free.
10.Slide latch head upward and remove it from door
frame with releasing latch spring from door frame and
latch head.
11.Now, latch head and latch spring are free.
12.Remove the glass stopper from the door frame.
13.Slide the front door glass leftwards and then slide
upwards to release the tabs holding it.
14.Now, the front door glass is free
RE-INSTALL
1. Re-install the front door glass to the door frame as
follows.
a) Insert the upper edge of the front door glass into the
four (4) tabs of the door frame.
b) Slide the front door glass downwards and insert the
lower edge of the front door glass into the four (4)
tabs of the door frame.
c) Slide the front door glass rightwards and insert the
right edge of the front door glass into the three (3)
tab of the door frame.
2. Re-install the glass stopper to the door frame.
3. Re-install the latch spring to the latch head. Re-install
the latch spring to the door frame. Re-install latch head
to door frame.
4. Re-install door panel to door frame by fitting two (2)
tabs of glass stopper to two (2) holes of door panel.
5. Hold the door panel to the door frame with four (4)
screws.
6. Located door panel hinge pins into cavity hinge loca-
tion hole.
7. Re-install choke cover  to door panel by clipping into
position.
Note: After any service to the door;
(A) Make sure that the monitor switch, monitored
latch switch and stop switch are operating prop-
erly. (Refer to chapter "Test Procedures".).
(B) An approved microwave survey meter should be
used to assure compliance with proper micro-
wave radiation emission limitation standards.
(Refer to Microwave Measurement Procedure.)
After any service, make sure of the following :
1. Door latch heads smoothly catch latch hook through
latch holes and that latch head goes through centre of
latch hole.
2. Deviation of door alignment from horizontal line of
cavity face plate is to be less than 1.0mm.
3. Door is positioned with its face pressed toward cavity
face plate.
4. Check for microwave leakage around door with an
approved microwave survey meter.  (Refer to Micro-
wave Measurement Procedure.)
Note:
Figure C-8. Door Replacement
DOOR REPLACEMENT
Page of 6
Display

Download Sharp R-795M (serv.man9) Service Manual (Repair Manual)