R-21ATP - Sharp Home Appliance Service Manual (repair manual). Page 17

Read Sharp R-21ATP Service Manual online

R-21ATP
15
25
INT1
IN
Signal synchronized with commercial power source frequency.
This is basic timing for all time processing of LSI.
26
P40
IN
Connected to GND through resistor.
27
RESET
IN
Auto clear terminal.
Signal is input to reset the LSI to the initial state when power is supplied.
Temporarily set to "L" level the moment power is supplied, at this time the LSI is
reset. Thereafter set at "H" level.
28
P71
OUT
Memory (EEPROM) clock output.
29
P70
IN/OUT
Memory (EEPROM) data input/output.
30
XIN
IN
Internal clock oscillation frequency setting input.
The internal clock frequency is set by inserting the ceramic filter oscillation circuit
with respect to XOUT terminal.
31
XOUT
OUT
Internal clock oscillation frequency control output.
Output to control oscillation input of XIN.
32
VSS
IN
Connected to GND.
33
P27
IN
Signal coming from touch key.
When either one of G-12 line keys on key matrix is touched, a corresponding signal
out of P30, P31, P32, P33, P34 will be input into P27. When no key is touched, the
signal is held at "L" level.
34
P26
IN
Signal similar to P27.
When either one of G-11 line keys on key matrix is touched, a corresponding signal
will be input into P26.
35
P25
IN
Signal similar to P27.
When either one of G-10 line keys on key matrix is touched, a corresponding signal
will be input into P25.
36
P24
IN
Signal similar to P27.
When either one of G-9 line keys on key matrix is touched, a corresponding signal
will be input into P24.
37-38
P23-P22
OUT
Terminal not used.
39-40
P21-P20
OUT
Segment data signals.
The relation between signals and indicators are as follows:
Signal
Segment
Signal
Segment
P21,P20 ........ 1
P05,P04 .......... 7
P17.P16 ........ 2
P03,P02 .......... 8
P15,P14 ........ 3
P01,P00 .......... 9
P13,P12 ........ 4
P11,P10 ........ 5
P07,P06 ........ 6
41-48
P17-P10
OUT
Segment data signal.
Signal similar to P21.
49-56
P07-P00
OUT
Segment data signal.
Signal similar to P21.
57-59
P37-P35
OUT
Terminal not used.
60
P34
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P27, P26, P25 and
P24 terminals while one of G4 line keys on key matrix is touched.
61
P33
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P27, P26, P25 and
P24 terminals while one of G5 line keys on key matrix is touched.
62
P32
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P27, P26, P25 and
P24 terminals while one of G6 line keys on key matrix is touched.
63
P31
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P27, P26, P25 and
P24 terminals while one of G7 line keys on key matrix is touched.
64
P30
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P27, P26, P25
and P24 terminals while one of G8 line keys on key matrix is touched.
Pin No.
Signal
I/O
Description
H : +5V
L : GND
20 msec
+5V
GND
ß(50Hz)
Page of 40
Display