R-21ATP - Sharp Home Appliance Service Manual (repair manual). Page 20

Read Sharp R-21ATP Service Manual online

18
R-21ATP
3) Practice for inputting total using times (Ex. 310000
times).
... Flashing /     ... 0.1sec BUZZER
PAD
DISPLAY
INDICATOR PHONE
(Door close)
.
.
CHECK
.
CHECK No.
CHECK
82 68
CHECK
(user total count)
SIGNAL
SIGNAL
DOUBLE
34 56
QUANTITY
(service total count upper figure)
3456XX
2
2
No.
(after 1 sec.)
78
(service total count lower figure)
XXXX78
1
1
No.
 (after 1 sec.)
34 56
SET
0
3,1,0,0
31 00
x 4
SET
31 00
2
2
No.
(after 1 sec.)
78
SET
0
0
0
SET
0
(service total count 310000 set)
CHECK
.
PROCEDURE FOR CHECKING/CLEARING
SERVICE COUNTS OF MICROWAVE OVEN
The following procedure enables the servicer to obtain the
total using times (cook cycles) since the microwave oven
is purchased and the total operation time (hours) since the
microwave oven is purchased. The maximum capacity of
the total using  is 999,999 times, and the maximum
capacity of total operation time is 999,999 hours.
1) Practice for checking total using times (Ex. 345678
times).
... Flashing /     ... 0.1sec BUZZER
PAD
DISPLAY
INDICATOR PHONE
(Door close)
.
.
CHECK
.
CHECK No.
CHECK
82 68
CHECK
(user total count)
SIGNAL
SIGNAL
DOUBLE
34 56
QUANTITY
(service total count upper figure)
3456XX
1 (No 1)
1
No.
(after 1 sec.)
34 56
(service total count upper figure)
2 (No 2)
2
No.
(after 1 sec.)
78
(service total count lower figure)
CHECK
.
2) Practice for checking total operation time (Ex. 4567
hours).
... Flashing /     ... 0.1sec BUZZER
PAD
DISPLAY
INDICATOR PHONE
(Door close)
.
.
CHECK
.
CHECK No.
CHECK
82 68
CHECK
(user total count)
SIGNAL
SIGNAL
DOUBLE
34 56
QUANTITY
(service total count upper figure)
3456XX
9 (No 9)
9
No.
(after 1 sec.)
45
(Total operation time upper figure)
0 (No 0)
0
No.
(after 1 sec.)
67
(Total operation time lower figure)
CHECK
.
4) Practice for inputting total operation time (Ex. 1234
hours).
... Flashing /     ... 0.1sec BUZZER
PAD
DISPLAY
INDICATOR PHONE
(Door close)
.
.
CHECK
.
CHECK No.
CHECK
82 68
CHECK
(user total count)
SIGNAL
SIGNAL
DOUBLE
34 56
QUANTITY
(service total count upper figure)
3456XX
9
9
No.
 (after 1 sec.)
45
SET
0
1,2
12
x 2
SET
12
0
10
No.
(after 1 sec.)
67
SET
0
3,4
34
x 2
SET
34
(Total operation time 1234 hours set)
CHECK
.
Page of 40