Read Sharp R-21ATP Service Manual online
10
R-21ATP
J
HIGH VOLTAGE FUSE TST
test across the two terminals as described in the below.
Table: Thermal Cut-out Test
Temperature of "ON"
Temperature of "OFF"
Indication of ohmmeter
Parts Name
condition (closed circuit).
condition (open circuit).
(When room temperature
(˚C)
(˚C)
is approx. 20˚C.)
Thermal cut-out 125˚C
This is not resetable type.
Above 125˚C
Closed circuit
Thermal cut-out 145˚C
This is not resetable type.
Above 145˚C
Closed circuit
If incorrect readings are obtained, replace the thermal cut-out.
An open circuit thermal cut-out (MG) indicates that the magnetron has overheated, this may be due to
resistricted ventilation, cooling fan failure or a fault condition within the magnetron or HV. circuit.
resistricted ventilation, cooling fan failure or a fault condition within the magnetron or HV. circuit.
An open circuit thermal cut-out (OVEN) indicates that the food in the oven cavity may catch fire, this may
be due to over heating produced by improper setting of the cooking timer or failure of the control panel.
be due to over heating produced by improper setting of the cooking timer or failure of the control panel.
CARRY OUT 4R CHECKS.
TEST PROCEDURES
PROCEDURE
LETTER
COMPONENT TEST
G
BLOWN FUSE M10A
CARRY OUT 3D CHECKS.
If the fuse M10A is blown when the door is opened, check the 1st. interlock switch, monitor switch and
monitor resistor.
monitor resistor.
If the fuse M10A is blown, there could be a short or ground in electrical parts or wire harness. Check
them and replace the defective parts or repair the wire harness.
them and replace the defective parts or repair the wire harness.
CARRY OUT 4R CHECKS.
CAUTION:
Only replace fuse M10A with the correct value replacement.
H
NOISE FILTER TEST
CARRY OUT 3D CHECKS.
Disconnect the leads from the terminals of noise filter.
Using an ohmmeter, check between the terminals as described
in the following table.
Disconnect the leads from the terminals of noise filter.
Using an ohmmeter, check between the terminals as described
in the following table.
MEASURING POINTS
INDICATION OF OHMMETER
Between N and L
Approx. 680 k
Ω
Between terminal N and WHITE
Short circuit
Between terminal L and RED
Short circuit
If incorrect readings are absorbed, replace the noise filter unit.
CARRY OUT 4R CHECKS.
I
MOTOR WINDING TEST
CARRY OUT 3D CHECKS.
Disconnect the leads from the motor. Using an ohmmeter, check the resistance between the two
terminals as described in the table below.
terminals as described in the table below.
Table: Resistance of Motor
Motors
Resistance
Fan motor
Approximately 219
Ω
Antenna motor
Approximately 11 k
Ω
If incorrect readings are obtained, replace the motor.
CARRY OUT 4R CHECKS.
FUSE
M10A
M10A
N
L
DISCHARGE RESISTOR 680 k
Ω
NOISE SUPPRESSION COIL
NOISE FILTER
LINE BYPASS
CAPACITOR
0.0033
CAPACITOR
0.0033
µ
F/ AC 250V
DISCHARGE
RESISTOR 10M
RESISTOR 10M
Ω
LINE BYPASS
CAPACITOR
0.0033
CAPACITOR
0.0033
µ
F/ AC 250V
LINE CROSS CAPACITOR 0.068
µ
F/ AC 250V
CARRY OUT 3D CHECKS.