AX-1100(R)M, AX-1100(SL)M (serv.man9). Error List - Sharp Home Appliance Service Manual (repair manual). Page 3

Read Sharp AX-1100(R)M / AX-1100(SL)M (serv.man9) Service Manual online

AX1100(R)M
10 – 3
2. How to check performance of thermistor (Engine) 
3. How to check thermistor (Grill) performance
4. EE01 thermistor (Grill) failure
✩ Before starting the P.W.B. unit replacement, make sure to refer to “Before replacing the Printed Wiring Board” in page 2-1.
YES
NO
Set the water tank, which has been filled with water to the MAX mark, to the set and power ON.
(Confirm that there is no water remaining in the oven cavity.)
Set the test mode to 10. (See How to operate test mode on page 11-1)
Press the START key.
The pump motor will operate for 30 seconds.
And then Microwave heating (for 1 minute) starts automatically.
Steam High operation (for 30 minutes) starts automatically.
After 2minutes, "CHECK" appears in the display automatically.
Is thermistor (Engine) failure (00 00 or 00 00 ) indicated?
EE12: Proceed to checking the thermistor (Engine) for failure.
Remove the water tank and press the START key.
The test mode 6 will be carried out and remained water in the engine
unit assembly will be evaporated
Normal termination (Indication: 11 11)
YES
NO
YES
NO
EE01: Proceed to checking the thermistor (grill) for failure.
Press the START key.
Does a measured value for the thermistor (grill) change as oven heating proceeds?
Is the measured value within ±10 bits with respect to the
standard value after about eight (8) minutes?
Set the test mode to 03.
(See How to operate test mode on page 11-1)
Power ON the main body.(Open and close the door.)
Press the STOP key to finish the operation. (This action is required when everything is OK.)
NO
YES
YES
NO
Measure the thermistor (grill) resistance using a tester with the thermistor
connecting connector pulled out of the wire harness.
The thermistor (grill) resistance is within its appropriate range.
Is the connector between the thermistor (grill) and wire harness either
disconnected or shorted?
Connect or repair the connector.
Replace the thermistor (grill).
Replace the control unit.
Page of 4
Display