UP-X300 (serv.man59). UP-X300 Version History 1.6.0.18 (This document contains all the specification changes and Bug fixes upto version 1.6.0.18) - Sharp EPOS Driver / Update. Page 5

Read Sharp UP-X300 (serv.man59) Driver / Update online

5
  1 x Melon
At KP accumulation the example b) is easier to understand for the person who realises the food preparation (meaning is that each of the
Condiment main item is prepared with the later printed tied condiments). The Condiments are accumulated regardless of the sequence the
items are entered and the KP print out is modified for better/easier understanding/preparation.
 A new parameter [KpCondimentTiedQtyModify ] in “X300_MainWindow.ini” file has been introduced.
3. Tied-Condiment with 0 price accumulation on the Bill
With the following settings the previous new specification introduced at the Enhancement_2 version was claimed.
Set the Bill layout to print tied condiments with 0 prices on the bill.
Set "Bill mandatory accumulation" at condiment programming to “No”.
Register 1 x Green salad with Yogurt and 1 x Green salad with French.
The bill print out look like:
2 x Green salad
     Yogurt
But the linked condiments items should not be accumulated and all should be printed.
Now all linked zero priced condiments are printed with the correct corresponding Qty.
The following items 1 to 11 are resolved problems
1. Compulsive table number entries
Pos programming / Employee / Revenue centre / Room / Table range
Even a table range was set for a Clerk a normal registration without table number entry was possible. Now only table registrations are possible
in such a case.
2. Customer Transaction Report in BO
Latest Print layout  is selected for Reports
A selected “Date Range” at the filter setting is printed correctly on the report now.
3. UP-X300 in network environment
Problems occurred in case many pre-set changes (changes with big data base files) were done at the BackOffice while registrations are
continued at another terminal in the system and the preset saving process (after leaving preset job) took a long time.
Sometimes at shutdown the message with “PLEASE WAIT” took a long time and it sometimes resulted in a POPUP error “Error in preservation
of the database”
After rebooting and power failure processing every think worked fine again
To prevent the above mentioned problems, the Time-Out of the “Service task” is extended from 1 minute to 20 minutes.
Page of 15