UP-X300 (serv.man59). UP-X300 Version History 1.6.0.18 (This document contains all the specification changes and Bug fixes upto version 1.6.0.18) - Sharp EPOS Driver / Update. Page 2

Read Sharp UP-X300 (serv.man59) Driver / Update online

2
5. No print of voided condiment with qty 0 on KP anymore.
Condition: KP accumulation is set to Total qty accumulation in / POS Programming / Products / Condiment List. Make a registration consist out
of f.e. one condiment and one article.
In the previous version, a voided not already printed condiment was printed on the Kitchen Printer with quantity 0.
Now a not printed but voided condiment will not be printed at all.
6. Delete of Customer Sales, Employee Sales, Employee Consumption and Employee Working Time at EOD.
It is possible to define whether the totalizer for Customer Sales, Employee Sales and Employee Working Time can be cleared during EOD or
not. Please refer to the setting in / POS Programming / Report Formats / EOD Report.
Customer sales data delete at daily End of Day
Yes/No. Default setting is No.
Employee sales data delete at daily End of Day
Yes/No. Default setting is No.
Employee time data delete at End of Day
Yes/No. Default setting is No.
X300
V1.6.0.18
The following items 1 to 2 are resolved problems
1. Clerk Terminal assignment.
At this version the preset of “Clerk – Terminal assignment” is also valid in case of using a Clerk Real Key system.
Previously this setting was only valid at Clerk Code entry and at the usage of Clerk direct keys.
2. Delete Customer Sales Data file.
At the print out of the Customer Turnover Report and deletion of the related files during EOD, only the Customer Transaction Base file was
deleted, but not the Customer Transaction Data file. The result was a growing Data file. Now, also the Data file will be erased at EOD.
X200
V1.2.0.18
The following item 1 is a specification changes or addition
1. Group discount with proportional dividing.
The individual calculation of the discount has not been divided to the different TAX groups correctly, if a group discount has been given in case
of a transaction of several articles which were assigned to different TAX rates. Now the proportional dividing will be work correctly.
X300
V1.6.0.16
X200
V1.2.0.16
[Compatibility]
The Version 1.6.0.16 is fully compatible with version 1.6.0.15. (All 1.6.x.x versions)
[OS versions]
UP-X300 OS version 1.07
UP-X200 OS version 1.23
The following item 1 to 3 are specification changes or addition
1.
  The lowest IP number of terminal is used to identify terminal of the .pos file for PMS software I/F
In order to identify which terminal a transaction has been performed at, the unique IP number will be sent from the terminal for identification
Page of 15