UP-X300 (serv.man45). UP-X300 Service Manual - Sharp EPOS Service Manual (repair manual). Page 14

Read Sharp UP-X300 (serv.man45) Service Manual online

UP-X300V
DIagnostics Specifications
3 – 8
(6) Target sector read test execution display
Select an item in each position indicated with "
"
(In the above display, the item surrounded by a 
 is selected and the
value surrounded by a 
 is selected.)
When, in the above display, "Pass count" is counted up and all the error
counters of all the error kinds are not counted up (remaining at 00000),
the test is OK.
The procedures to interrupt, resume, and terminate the test are the
same as those of the above (3). 
(7) HD dump test execution display
Select an item in each position indicated with "
"
(In the above display, the item surrounded by a 
 is selected and the
value surrounded by a 
 is selected.)
The above display shows the contents of former 256 byte in the position
of 000 LBA sector. Press [PGDN] key to display the latter 256 byte. 
(When [PGDN] key is pressed on the above menu, the latter half of 256
byte in the position of 000 LBA sector is displayed.) Press PGDN key to
display the former 256 byte. 
When [ESC] key is pressed, the display returns to the menu display of
the previous (1).
(8) Disk controller check test execution display
When the pass count is counted up and "OK!" is displayed at stop, the
test is OK. (Note that it takes several seconds for 1 pass.)
When [SPACE] key is pressed during the test, the test is interrupted. 
When [SPACE] key is pressed during interruption of the test, the test is
resumed.
When [ESC] key is pressed during execution or interruption of the test,
the test is terminated and the display returns to the menu display.
(9) Smart ON/OFF execution display
The status of the smart function is displayed in the position of "*"
Press [ENTER] key to turn ON/OFF the smart function. When [ESC]
key is pressed, the display returns to the menu display of the above (1).
Refer to HDD SMART.DOC.
(10) SMART value screen
SMART values stored in HDD are displayed.
Legends
With the above screen displayed, select YES using the cursor keys and
then press ENTER to save the values displayed in the file.
You can exit the program without saving the values, by selecting NO
and then pressing ENTER or ESC.
Target Sector Read test
LBA range 
?
Error Kinds
Drive not ready
Sector count ?
Bad controller
[Error stop continue 1 pass]
Test Start ?[ Yes  No]
Pass count=xxxxx
Test Point=xxxxxxxx (LBA)
[0000000-194608791]
[0-63]= 63
Retry count  ?
[0-4]= 0
ESC:Exit      SPACE:Stop       Start
Error details content
or
HD Dump test
Physical address ? [CCCC.HH.SS]= 0000 .  00 . 01
The first half sector
 0 0 0 :HH HH     HH HH-|HH HH   HH HH  AAA   AA
(1 0 0)
 0 1 0 :HH HH     HH HH-|HH HH   HH HH  AAA   AA
 0 2 0 :HH HH     HH HH-|HH HH   HH HH  AAA   AA
 0 F 0 :HH HH     HH HH-|HH HH   HH HH  AAA   AA
(1 F 0)
PGDN:forward     PGUP:Fback    SPACE:Start     ESC:Exit
(1 1 0)
(1 2 0)
XXXXXXX
: The meaning of each SMART value is displayed.
If an unknown value is read, the ID number is displayed.
cur
: The current value of each item.
wor
: The worst value of each item in the past.
thr
: The lowest value at which each item operates normally.
Disk Controller Check test
[Error stop continue 1 pass]
Test Start ?[ Yes  No]
Pass count=xxxxx
Controller   Checking
ESC:Exit     PACE:Stop        Start
or
Smart ON/OFF
SMART [ON or OFF]
ESC:Exit
ENTER:Exceute
*
Smart Value Display
cur : wor : thr
cur : wor : thr
XXXXXXX : xxx : xxx : xxx
‚w‚w‚w‚w‚w‚w : xxx : xxx : xxx
‚w‚w‚w‚w‚w‚w : xxx : xxx : xxx
XXXXXXX : xxx : xxx : xxx
‚w‚w‚w‚w‚w‚w : xxx : xxx : xxx
Value Save ? [ YES NO ]
CURSOR: Move         ENTER: Select             ESC: Exit
Page of 73
Display