DIagnostics Specifications
3 – 11
(4) LCD attribute test execution display
When any key is pressed, the test is terminated and the display returns
to the menu of the test (1) above.
(5) VRAM test
Enter [SPACE] key to execute the VRAM verify test. (The display is colored in
12 colors.) Check the display and press any key to display the test result.
When [ESC] key is pressed, the display returns to the menu display. 
(6) LCD Brightness TEST screen
You can decrease the brightness by pressing the [
1] key and increase it by
pressing the [
3] key.
The display will be returned to the menu screen by pressing the [ESC] key.
4-6. RTC
4-6-1. General
This test is used to check the RTC (Real Time Clock).
The following test items are checked:
• RTC test: Calendar time alarm setting test, calendar time alarm data
read test, timer interruption test
• CMOS RAM test: Marching test, sequential write/read-verify test, RAM
display test, RAM battery backup test
•  Other functions: Error information display
4-6-2. Required Tools to be used
•  UP-X500 series main unit diag execution media   x 1
4-6-3. Test item
The purpose of this test are as follows:
4-6-4. Test contents
(1) Calendar & clock setup test
This test is used to set data of calendar, clock, and alarm for the RTC. 
(2) Calendar & clock real test
This test is used to read and display the calendar, clock, and alarm data
of the RTC.
(3) Timer interrupt test
This test is used to execute the update test of the RTC calendar and clock.
The following timer interrupt items are also checked:
• Periodic interrupt
• Alarm interrupt
• Update ended interrupt
(4)CMOS RAM marching test
Caution: During execution of this test, do not turn off the power and do
not reset the unit.
[Test condition setting]
• Error/Stop/Continue/1 pass
[Test contents]
The test pattern data are written into the area (Index address 0Eh - 7Eh) of
the CMOS RAM, and the read/verify test is executed.
After writing the data, the read/verify test is executed only once. 
There are four kinds of data pattern to be written: 00h, FFh, 55h, and AAh.
Writing the above four patterns form 1 pass. 
Before execution of the test, save all the data in the CMOS RAM. After exe-
cution of the test, restore the data to the CMOS RAM.
(5) CMOS RAM sequential write/read-verify test
Caution: During execution of this test, do not turn off the power and do
not reset the unit.
[Test condition setting]
• Error/Stop/Continue/1 pass
[Test contents]
The test pattern data are written into the area (Index address 0Eh -
7Eh) of the CMOS RAM, and the read/verify test is executed.
After writing the data, the read/verify test is executed twice.
Leave an interval (1 sec) between the first check and the second check. 
There are following patterns of data to be written: (Data of 1 pass)
Before execution of the test, save all the data in the RAM. After execu-
tion of the test, restore the data to the RAM.
BLACK
BLUE
GREEN
CYAN
RED
MAGENTA
BROWN
LIGHT-GRAY
DARK-GRAY
LIGHT-BLUE
LIGHT-GREEN
LIGHT-CYAN
LIGHT-RED
LIGHT-MAGENTA
YELLOW
WHITE WHITE
BLACK
BLUE
GREEN
CYAN
RED
MAGENTA
BROWN
LIGHT-GRAY
BLACK
BLUE
GREEN
CYAN
RED
MAGENTA
BROWN
LIGHT-GRAY
Press any key to exit
WHITE
Reverse
display
Blink
display
VRAM test
SPACE:Stop      ESC:Exit
LCD Brightness Test
Low - - - - - - - o - - - - High
Left: BrightnessDown         Right: BrightnessUp          ESC: Exit
Calendar & clock setup test
Calendar & clock read test
Timer interrupt test
CMOS RAM marching test
CMOS RAM sequential write/read-verify test
CMOS RAM display test
CMOS RAM battery backup test
Error table display
Calendar
Clock
Alarm
: Year/Month/Day/Day of week
: Hour/Minute/Second
: Hour/Minute/Second
Test pattern (I) 00h, 01h, 02h, 04h . . .  40h, 80h (9 patterns)
Test pattern (II) FFh, FEh, FDh, FBh . . .  BFh, 7Fn (9 patterns)
Test pattern (III) 00h, 01h, 02h, 03h . . .  FEh, FEh (256 patterns)