UP-X300 (serv.man45). UP-X300 Service Manual - Sharp EPOS Service Manual (repair manual). Page 10

Read Sharp UP-X300 (serv.man45) Service Manual online

UP-X300V
DIagnostics Specifications
3 – 4
(3) Target Sector Read Test execution display
Select an item in each position indicated with "
"
(In the above display, the item surrounded by a 
 is selected and the
value surrounded by a 
 is selected.)
When, in the above display, "Pass count" is counted up and all the error
counters of all the error kinds are not counted up (remaining at 00000),
the test is OK.
Procedures to interrupt, resume, or terminate the test are similar to the
above (3). 
(4) Sequential Write/Read & Compare Test execution display
Similar to the above (3). The different points are as follows:
Cylinder scope  ?
Drive_A [01 - 79] items differ from those in (3). (Different points are indi-
cated with 
.)
Test mode: 
Different points from (3) are indicated with a rectangle.
(5) Target sector write/read & Compare test execution display
Similar to the above (3). The different points are as follows:
Test mode: 
Different points from (3) are indicated with a rectangle.
4-2-6. Error contents
(1) Sequential read only test
(2) Target sector read test
• 
Bad command
(A command is terminated abnormally. (Under BIOS CALL INT13H status))
• 
Bad address mark
(The address mark cannot be found. (Under BIOS CALL INT13H status))
• 
Write protect 1
(The disk is set to write-protect. (Under BIOS CALL INT13H status))
• 
Record not found
(The sector cannot be found. (Under BIOS CALL INT13H status))
• 
Diskette change
(The diskette was changed. (Under BIOS CALL INT13H status))
• 
Bad DMA boundary
(A DMA overrun occurs. (Under BIOS CALL INT13H status))
• 
Bad error
(An abnormality occurs in the CPU. (Under BIOS CALL INT13H status))
• 
Bad controller
(A trouble occurs in the controller. (Under BIOS CALL INT13H status))
• 
Seek error
(A trouble occurs in seek operation. (Under BIOS CALL INT13H status))
• 
Time out error
(Time out occurs or the drive is not ready. (Under BIOS CALL INT13H
status))
• 
Other error
(An error other than the above occurs. (Under BIOS CALL INT13H status))
• 
Recalibrate error
(An error occurs when recalibrate is executed.)
• 
DSK not ready
(There is no floppy disk in the FD drive or the floppy disk is not formatted.)
(3) Sequential write/read & compare test
(4) Target sector write/read & compare test
• Compare error
(When the write data differ from read data, this error occurs.)
4-3. IDE I/F & Hard Disk (Std & Opt)
4-3-1. Outline
This test is used to display information on the installed hard disk and the
option hard disk test and data in the hard disk.
The test items are as follows:
• Read test: Seek (sequential) test, read only (target cylinder, target
sector), dump test
•  Write test: Write verify (target cylinder, target sector), patch test
• Other test: Drive status display, controller check, smart function ON/
OFF, error information display
4-3-2. Required Tools to be used
UP-X500 series main unit diag execution media  x 1
4-3-3. Test items
The purposes of this test are as follows:
[Read mode test]
[Write mode test]
When data write
displayed.
When data compare 
When data write
displayed.
When data compare 
Error details content
(Cylinder, head, celector)
(hour : minute : sound)
Target sector read test
Error Kinds                  Drive_A
Bad command             xxxxx
Bad Address Mark       xxxxx
Recalibrate error         xxxxx
Test mode :  Read    Test drive : Drive_A
Pass count = xxxxx
Test Point=CC,H,SS
TIME HH:MM:SS
Test Start ? [ Yes   No]
Test drive ? [ Drive_A]
Cylinder scope ?
Drive_A (1.44MB)
Sector count ?
Error stop ?
Retry Count ? [0      4] =  0
[error stop  continue  1 pass]
[00     79] = 00
Head number ?
[01     18(MAX9)] =  01 - 09
[0     1] =  0
ESC:Exit
SPACE:Stop
Start
or
write
verify
write
verify
• Drive status display
• Sequential seek test
•  Seek & read test
• Read test
•  Target sector read test
•  HD dump test
• Current check test
• Smart ON/OFF
• Smart value display
•  Seek & write/read-verify test
• Write/read-verify test
•  Target sector write/read-verify test
• HD patch test
• Error table
Page of 73