Sharp Technical Update
4 of 5
MCR - OPOS software configuration.
In order for the UPV5500 to communicate correctly to the MCR via OPOS the
following procedure must be performed.
1.
Ensure that the MCR hardware has been correctly installed.
2.
Power on the UPV5500
3.
From within Windows select – Start – All Programs – VCT OPOS Drivers
– Tools – MSR Configuration
4.
From within the MSR configuration Tool, Select File – Setting – ensure
that the Port=COM7 and the Baudrate=19200
5.
From the main MSR Configuration Tool screen ensure that the settings
are shown as above (these should be already set)
6.
Select the ‘Write the setting’ button.