DIAGNOSTICS SPECIFICATIONS
4 – 2
3. SERVICE DIAGNOSTICS
3-1. SERVICE DIAGNOSTICS GETTING STARTED
GETTING STARTED:
Execute “SRV.BAT” by entering the command with the PS2 keyboard
as follows:
A:\> SRV 
b
“A:\>” is the DOS prompt. (Used by the FD)
*
Do not load any device drivers when using this program.
*
To operate other applications after performing this program, it is rec-
ommended to re-boot the machine.
3-2. SELECTION MENU
The diagnostics menu is started and the following menu is displayed. 
The highlighted cursor is moved by the cursor keys (UP 
2
 and 
DOWN 
4
 ) of the PS2 keyboard. Move the cursor to the desired item,
and press the Enter key to execute the selected diagnostics program.
When the selected diagnostics program is completed, the display
returns to the menu screen by pressing the ESC key. Select “Diagnos-
tics End” and press the Enter key to terminate the diagnostics.
3-3. RAM DIAGNOSTICS
This program is used to test the standard memory and the extension
memory.
1) D-RAM CHECK
1
Checking content
All memory areas are checked in blocks of 512KB. The checking
procedures are as follows:
i.
Test data 5555H is written to all the test areas.
ii.
Test data and read data are compared by each word, If it is
O.K., test data AAAAH is written to the test area.
iii. Test data and read data are compared by each word, If it is
O.K., test data 5555H is written to the test area.
iv. Test data 0000H is written to all the test areas.
v.
Test data and read data are compared by each word, If it is
O.K., test data FFFFH is written to the test area.
vi. Test data and read data are compared by each word, If it is
O.K., test data 0000H is written to the test area.
When an error occurs during the test, the error address and data are
displayed and the test is stopped.
For the extended memory test, the value is set in the setup of the
read test and is made to the area in increments of 512KB.
2
Display
The error address and the error data are displayed only when an
error occurs. (When no errors occur, they are not displayed.)
3
Terminating method
After completion of the test, press the Esc key to terminate and
return to the service diagnostics menu.
RAM Diagnostics
Diagnostics for Service
SHARP PC-POS System Diagnostic Series      
ROM Diagnostics
Real time clock & CMOS RAM Diagnostics
Tou ch Panel Diagnostics
Key Pad Diagnostics
Version  1.00A
Clerk Key Diagnostics
Serial I/O Diagnostics
Printer Diagnostics
LCD (Liquid Crystal Display) Diagnostics 
MCR (Magnetic Card Reader) Diagnostics
System Switch Diagnostics
Drawer Diagnostics
Diagnostics End
IDE I/F & Controller Diagnostics
Option Display Diagnostics
FAN&LCD ON/OFF Diagnostics
FDD Diagnostics
Power Hold Diagnostics
IV
D-RAM Check
Memory size   : xxxxKB         PAS S !!(or ERROR !!)
Error Address  xxxxxxH    Write Data  xxxxH    Read Data  xxxxH
Page of 127
Display