UP-5900 (serv.man8). UP5900 Service Manual - Sharp EPOS Service Manual (repair manual). Page 9

Read Sharp UP-5900 (serv.man8) Service Manual online

UP-5900VS
OPTIONS
2 – 4
5. SERVICE TOOLS
5-1. PARALLEL LOOP BACK CONNECTOR: 
UKOG-2366BHZZ
This connector is connected between CN10/11 of the main PWB and
the parallel port through the Dongle cable (QCNW-7858BHZZ) for
checking the parallel port during execution of diagnostics.
5-2. MCR TEST CARD: UKOG-6718RCZZ
•  Used when executing the diagnostics of the UP-E12MR2.
• External view
5-3. RS232 LOOP BACK CONNECTOR:
UKOG-6705RCZZ
Connected to the RS232 connector (D-SUB 9 pin: COM1, COM2) of the
UP-5900 and ER-A8RS, and used to check loop signals when execut-
ing diagnostics.
• Connection diagram
5-4. RS232 MODULAR JACK LOOP BACK
CONNECTOR: UKOG-6729BHZZ
Connected to the RS232 connector (RJ45: COM3) of the UP-5900, and
used to check loop signals when executing diagnostics.
• Connection diagram
No.
NAME
PARTS CODE
PRICE
DESCRIPTION
1
Parallel loop back connector
UKOG-2366BHZZ
BM
2
MCR test card
UKOG-6718RCZZ
BE
for UP-E12MR2
3
RS232 loop back connector
UKOG-6705RCZZ
BC
for RS232 connector
4
RS232 modular jack loop back connector
UKOG-6729BHZZ
AZ
for RJ45 connector
5
TOUCH PEN
CPENP1004PCN5
AG
STROBE#
1.   D0
2.   D1
3.   D2
4.   D3
5.   D4
6.   D5
7.   D6
8.   D7
9.   ACK#
10. BUSY
11. PE
12. SLCT
13. AF#
14. ERROR#
15. INIT#
16. SLCTIN#
17. PE
25. PE
CD       1pin
RD       2pin
TD       3pin
DTR    4pin
GND    5pin
DSR    6pin
RTS    7pin
CTS    8pin
RI        9pin
RTS
DTR
TD
GND
GND
RD
DSR
CTS
1pin
2pin
3pin
4pin
5pin
6pin
7pin
8pin
Page of 127