UP-5300 (serv.man4). UP5300 Option Installation Manual - Sharp EPOS Service Manual (repair manual). Page 10

Read Sharp UP-5300 (serv.man4) Service Manual online

*
 How to Extend Display Pole
The pole can be extended by installing the attached pole to the
standard pole.
COMPONENT LIST:
No.
NAME
USE
Q’ty
7
G
Pole cabinet
Pole extension
2
H
Screw (M3 
×
 4)
Pole connection
4
I
Screw (M4 
×
 16)
Securing the UP-P20DP to
the wooden table
4
J
Screw (M4 
×
 20)
Securing the UP-P20DP to
the metal table
4
K
Nut
Securing the UP-P20DP to
the metal table
4
L
Display cable (S)
This display cable (S)
should be used instead of
the standard cable and
earth wire if the UP-20DP’s
standard pole is removed
to lower the height of the
UP-20DP.
1
M
Earth wire (S)
1
  1) Remove the five screws 
1
.
  2) Remove the Base angle 
2
.
  3) Remove the PWB unit 
3
 from the Base cabinet 
4
.
  4) Remove the display cable 
5
 from the PWB unit 
3
.
  5) Remove the two screws 
6
.
  6) Remove the Base cabinet 
4
 from the pole cabinet 
7
.
  7) Pull the Ratchet 
9
 attached to the pole cabinet 
7
 out of the
Display unit 
8
 by turning it as shown in Figure A.
  8) Remove the two screws 
F
.
  9) Remove the pole cabinet 
7
 from the Ratchet 
9
.
Pattern side(PWB)
Core
1
2
3
4
5
1
6
4
7
7
8
9
10
10
9
UP-5300VI
– 9 –
Page of 21