62. 
Detailed General Report data print on Journal and in E/J.
At the former ROM-Version, only the General Z1 and Z2 -Report were printed on the journal in
detailed format, but not the X-Reports. In the E/J, every General X1/Z1 and X2/Z2 Report were
printed with the header only.
If the new service parameter, SRV #986C is set to +4, the print format for the General Reports
on journal printer as well as for the E/J is detailed.
Detailed General Report data print on Journal and in E/J
986-C
Default
Header only
0
Detailed
4
63. 
Improve display in PLU/EAN stock control mode and scanning possibility.
At the PLU/EAN list in stock control menu, the current stock for each item is shown now.
Furthermore, in the PLU/EAN stock entry mask, the article number as well as the article text is
displayed in bold characters. If the text length of the article number and text reaches the width
of the entry window, the article number and text property changes back to normal characters
size.
Within this mask it is also possible to jump to another EAN simply by scan the EAN code. This
new behaviour makes the entry of stock values very comfortable. Simply after entering the new
stock value, scan the new article. The already entered value will be saved and the new,
scanned, article will be displayed in the mask.
64. 
Print out of Bill- Header and Footer on E.Bill.
By setting the existing parameter SRV #928A to 1, the Bill -Header and –Footer will be printed
on the bill, but not on the E.Bill. By this version, when this parameter is set, the Bill –Header and
–Footer will be printed on the E.Bill as well.