48. 
Setting of ESC-Sequences for half and full cut.
In order to connect printers which do have other escape sequences for full respectively half cut,
a new possibility of entering flexible escape sequence is available. In SRV\SETTING\DEVICE
CONFIG there is a new menu entry “CUSTOMIZER PRINTER” where the sequences can be
entered. Each entry consists out of max. 8 byte. Only the characters ‘0-9’, ‘a-f’, ‘A-F’ and the ‘,’
are allowed to enter. The proofing for invalid characters will be done by leaving the
programming. Each byte consists out of 2 digits and must be comma separated. The first
number represents the total length of the escape sequence include the length byte. If i.e. the
escape sequence 1D,56,01 should be used for the new sequence the entry has to look like as
the sequence in the below shown picture.
Remark: The entry of this programming menu via PGM at a Satellite is prohibited. This setting
will also not be distributed by service parameter download in inline system.
49. 
Scroll message in customer display.
Because the scroll speed for the pole display was too slow, the speed becomes settable. In
PGM2 MODE\SETTING\MESSAGE\MESSAGE OPTIONS\ three new parameters are available
now. It is possible to set the speed for the UP-3500 LCD screen saver and for the optional
customer pole display. Furthermore the interval for the customer pole display is settable as well.
Valid values are: LCD DISP. SPEED
0 ~ 99
POLE DSP INTERV.
0 ~ 99
POLE DSP. SPEED
0 ~ 97
As higher the values are, as higher is the speed.
50. 
Clear GLU information in REG window.
The GLU number of a previous transaction will remain in the display. This is somehow
confusing at the start of the next registration. With this version, it is selectable if the GLU
number after finalize should be cleared or not.
The related parameter is PGM2 MODE\SETTING\OPTIONAL\FUNCTION SELECT2\CLEAR
GLU# DISP.