36
2. Setting the terminal numbers (IRC machine numbers) —
master and satellite
It is assumed that your terminal has been set for inline operations.
1.
Enter the PGM2 mode.
2.
Select “SETTING” and touch the 
ENTER
 key.
3.
Select “INLINE CONFIG” and touch the 
ENTER
 key.
4.
Enter a terminal number for IP ADDRESS 4 from (0–
254) and touch the 
ENTER
 key.
(For programming for BMA MACHINE No. and
SYSTEM RETRY function, see pages 39–40.)
5.
Repeat steps 1 to 4 for all machines in the IRC
system.
NOTE
• Terminal numbers must be assigned to the master and each satellite in the IRC system.
(For setting the master’s terminal number, see the next paragraph.)
• If an inline network contains two or more machines with the same terminal number, IRC
communications will not be achieved correctly. Each terminal number must be unique.
• The terminal number should be within the range from 1 to 254.
• If the terminal number “000” is programmed for a machine, it is put in the OFF LINE mode and
cannot take part in IRC communications.