PROGRAM MODE
2 – 8
[JOB#8] EURO FUNCTIONS    -- ABCD --
MRS = 0000
[JOB#10] POWER SAVING    -- YXXX --
MRS = 0030
[JOB#11] LOGO PRINTING    -- A --
MRS = 3
1, 2 and 4 setting is not used.
[JOB#12] EURO Programming    -- AB --
MRS = 00
[JOB#13] The date of exchanging the currency between
LOCAL and EURO    -- XXXXXXXX --
MRS = 00000000 (DD/MM/YYYY)
DATE) XXXXXXXX :YYYYMMDD or DDMMYYYY or MMDDYYYY
[YYYY:2000-2099]
[MM:01-12]
[DD:01-31]
00000000 = Function Inhibit.
The date entry format complies with the applicable PGM-mode pro-
gramming.
In case of date setting is 0, EURO date function is not work.
[JOB#14]  The Time (hour only) of exchanging the currency
between LOCAL and EURO    -- XX --
MRS = 00
XX : Hour (00-23)
[JOB#15]
FUNCTION SELECT2
-- ABCDEFGH --
MRS = 00011010
[JOB#30] RS-232C TERMINAL No.    -- XXXXXX --
MRS = 000001
XXXXXX : Terminal number
G: NET AMOUNT PRINTING
G
PRINT
0
NOT PRINT
1
H: PURCHASE NO. PRINTING
H
PRINT 0
NOT PRINT
1
A: Printing of EX amount for Total and Change
A
No
0
Yes
1
B: Not used (Fixed at “0”)
C: CHECK,CREDIT operation for EX1
C
No
0
Yes
1
D: EXCHANGE Calculation method
D
Multiplication
0
Division
1
Y: POWER SAVING function when a time is displayed
Y
Yes (Enable)
0
No (Disable)
1
XXX: POWER SAVING TIME to POWER OFF
= 001--254 (minutes)
   or  999 (Inhibit)
A: LOGO MESSAGE CONTROL
A
3-LINE HEADER INSTEAD OF GRAPHIC LOGO
0
6-LINE HEADER
3
3-LINE HEADER AND 3-LINE FOOTER
5
A: Automatic converting the unit price at EURO
A
YES
0
NO
1
B: The EURO CHANGING JOB at the date of exchang-
ing the currency between LOCAL and EURO.
B
Compulsory
0
Non-compulsory
1
A: PLU SHIFT LEVEL reset
A
AUTO
0
MANUAL
1
B: PLU LEVEL SHIFT
B
REG & MGR
0
MGR only
1
C: PLU SHIFT LEVEL AUTO reset timing
C
1 item
0
1 receipt
1
(This setting is available in case "PLU SHIFT LEVEL reset = AUTO")
D: Checking of CLERK# on guest check when a reorder
is made
D
Yes
0
No
1
E: Printing of PB/NBAL on G.C.RCPT
E
Yes
0
No
1
F: Clear details in GLU buffer at NBAL
F
No
0
Yes
1
G: Clear details in GLU buffer at BILL(G.C.RCPT) print
G
No
0
Yes
1
H: Not used (Fixed at “0”)