CODE : 00Z
q
CONTENTS
Parts marked with "
!
" are important for maintaining the safety of the set. Be sure to replace these parts with specified
ones for maintaining the safety and performance of the set.
SHARP CORPORATION
PROGRAMMING MANUAL
XEA212VPME
ELECTRONIC
CASH REGISTER
 MODEL
XE-A212
      
(For “V” version)
CHAPTER 1. MASTER RESET AND PROGRAM RESET  . . . . . . 1 - 1
CHAPTER 2. PROGRAM (PGM2/PGM1) MODE  . . . . . . . . . . . . . 2 - 1
CHAPTER 3. OP X/Z, X1/Z1, X2/Z2 MODE. . . . . . . . . . . . . . . . . . 3 - 1
XE-A212
MASTER RESET and program reset
1 – 1
CHAPTER 1. MASTER RESET AND PROGRAM RESET
1. MASTER RESETTING
Master resetting clears the entire memory and resumes initial values.
Master resetting can be accomplished by using the following procedure:
Procedure :
1) Unplug the AC cord from the wall outlet, or set the mode switch to OFF position.
2) Let the ECR be witout the memory backup battery.
3) Wait over 1 minute for discharging.
4) Set the mode switch to any position except OFF.
5) Plugin the AC cord to the wall outlet, or turn the mode switch from OFF position to another position.
6) Insert batteries before carrying out operation after master resetting.
The master reset can also be accomplished in the following case.
In case power failure occurs when the machine has no battery attached to it, the master reset operation is automatically performed after the power
has been restored.
(This is because if power failure occurs with no battery attached to the machine, all the memories are lost and the machine does not work properly
after power recovery; this requires the master reset operation.)
2. PROGRAM RESETTING (INITIALIZATION)
This resetting resumes the initial program without clearing memory.
This resetting can be operated at below sequence in PGM mode.
Procedure:
1) Unplug the AC cord from the wall outlet.
2) Wait over 1 minute for discharging.
3) Set the mode switch to the PGM position.
4) While holding down the FEED key, plugin the AC cord to the wall outlet.
Note: In case power failure occurs when the machine has no battery attached to it, the master reset operation is automatically performed after the
power has been restored.
XE-A212
PROGRAM MODE
2 – 1
CHAPTER 2. PROGRAM MODE
1. READING STORED PROGRAMS
The machine allows you to read every program stored in the PGM mode.
 
Key sequence for reading stored program
Note: To stop reading programming report, turn the mode switch to the MGR position.
 SAMPLE PRINTOUTS
1. Programming report 1
Report name
Key sequence
Programming report 1
Programming report 2
Auto key programming report
Printer density programming report
Department programming report
PLU programming report
TL
TL
TL
TL
TL
Start PLU code           
End PLU code
PLU/SUB
Mode
Function no.& its text
Function parametrs (B-D)
Function parametrs (B-D)
Discount amt. w/sign
Percent limit
Logo Message
Print format (A-H)
Receipt print format(A-H)
EURO system settings (A-D)
Power save mode(A-D)
Logo message print format
Automatic EURO modification 
operation settings (AB)
Percent rate with sign
Entry digit limit
Function parameters (A-C)
Foreign currency 
symbol/Rate
Function selection for 
miscellaneous keys (A-H)
Tax rate
Min. taxable amount
Clerk code/name
Time setting for EURO
modification operation
PLU level shift and 
GLU function parameters
Date setting for EURO
modification operation
*Job code #30 to #35 are
  fixed settings, for which you
 cannot change the settings.
XE-A212
PROGRAM MODE
2 – 2
2. USER PROGRAMMING
1) PRICE PROGRAMMING FOR DEPT.& (-) KEYS
If a price is set for a department which amount entry type is “INHIBIT” or
“OPEN”, its amount entry type is set as below automatically.
MRS = 0
2) DEPT FUNCTION PROGRAMMING
2  Programming report 2
Job code
A to H from the left
Training clerk specification
Training mode text
Language selection
EJ memory type
* Job code #65, 70, 71, 72, 
76, 77 and 95 are fixed 
settings, for which you 
cannot change the 
settings.
3  Printer density programming report
Entered value
Printer density
Printing density
example
4  Department programming report
Dept. unit price 
w/sign
Dept. function
Minus department
Tax status
Dept. code
Dept. text
5  PLU programming report
PLU code
PLU text
Mode parameter
Unit price
Range
Associated
dept. code
YY: Department Code (01-50)
XXXXXX: Unit price (Max. 6 digits)
“PRESET”
”INHIBIT”
“OPEN & PRESET”
1
 ”OPEN”
YY: Department code (01-50)
A: Taxable 4
A
No
0
Yes
1
B: Taxable 3
B
No
0
Yes
1
C: Taxable 2
C
No
0
Yes
1
D: Taxable 1
D
No
0
Yes
1
E: REGISTRATION TYPE
E
NORMAL
0
SICS
1
F: SIGN
F
+
0
-
1
G: LIMITATION DIGITS = 0 to 8
0 : OPEN PRICE REGISTRATION INHIBIT.
XXXXXX
YY
XXXXXX
0
0
TL
DPTn
DEPT#
ST
(-)
ABCDEFGH
ABCDEFGH
YY
0
0
TL
DPTn
DEPT#
Page of 24
Display

Download Sharp XE-A212 (serv.man2) Service Manual (Repair Manual)

Here you can read online and download Sharp XE-A212 (serv.man2) Service Manual in PDF. XE-A212 (serv.man2) service manual will guide through the process and help you recover, restore, fix, disassemble and repair Sharp XE-A212 (serv.man2) ECR. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.