[JOB#70] OTHERS10 PROGRAMMING   -- ABCDEFGH --
MRS = 01000000
[JOB#71] GT2 PROGRAMMING   -- XXXXXXXXXXXXX --
MRS = 0000000000000
XXXXXXXXXXXXX : GT (13digits)
[JOB#72] GT3 PROGRAMMING   -- XXXXXXXXXXXXX --
MRS = 0000000000000
XXXXXXXXXXXXX : GT (13digits)
[JOB#76] GENERAL Z1 RESET REPORT COUNTER
-- XXXX --
MRS = 0000
XXXX : RESET COUNTER (4digits)
[JOB#77] GENERAL Z2 RESET REPORT COUNTER
-- XXXX --
MRS = 0000
XXXX : RESET COUNTER (4digits)
[JOB#86] TRAINING CLERK PROGRAMMING    -- XX --
MRS = 0
X : CLERK No. = 0 (INHIBIT), 1 to 10
22) DOMESTIC CURRENCY SYMBOL PROGRAMMING
(CHARACTERS): CHARACTER (Max. 4 Characters)
Characters can be entered by using the character layout on keyboard or
using numeric keys on keyboard.
THE KEY ENTRY SEQUENCE FOR ENTERING ONE CHARACTER
BY NUMERIC KEYS IS AS FOLLOWS:
YYY 
3 [00] KEY
YYY : CHARACTER CODE (3 DIGITS)
          (or [000] KEY ACCORDING TO PGM PRESET)
MRS = ___*    ( _: space code)
This symbol is printed with (+) amount of domestic currency.
The programmed characters is printed at left side of amount.
Ex) Case of “    DM”:
        | DEPT.01             DM1.00  |
                                        
2
                      Programmed symbol
If some space characters are programmed at the left side of symbol
(like “   *”), they are not counted as the number of character of the cur-
rency symbol. (In case of “   DM”, the number of character is 2.)
Ex) Case of “  DM”: (The currency symbol means “DM”)
        |AAAADEPARTMENT01  DM10000.00  |
                                                   
2
                                 Programmed symbol
23) TRAINING MODE TEXT PROGRAMMING
(CHARACTERS): CHARACTER (Max. 12 characters)
Characters can be entered by using the character layout on keyboard or
using numeric keys on keyboard.
THE KEY ENTRY SEQUENCE FOR ENTERING ONE CHARACTER
BY NUMERIC KEYS IS AS FOLLOWS:
YYY 
3 [00] KEY
YYY : CHARACTER CODE (3 DIGITS)
          (or [000] KEY ACCORDING TO PGM PRESET)
MRS = **TRAINING**
24) TEXT CHANGING (TO DEFAULT TEXT)
X:  0 = English text
1 = German text
2 = French text
3 = Spanish text
MRS = 0
 When this job is executed, below texts are set as default data.
(a) Function text
(b) Each message text (LOGO, etc..)
(c) Clerk name
25) RESETTING OF ALL COUNTER AND TOTALIZER
All counter, totalizer, all GTs, and all Z counter are reset.
EJ data does not cleared at this job. (EJ data is cleared by using XZ resetting.)
A: Not used (Fixed at “0”)
B: EJ Z-Report with data print
B
No
0
Yes
1
C, D, E, F, G, H: Not used (Fixed at “000000”)
(CHARACTERS)
ST
ST
85
TL
NO CHANGE
(CHARACTERS)
ST
ST
87
TL
NO CHANGE
X
ST
88
TL
0
*'#&'4
2/
DATE/TIME/CLERK NO 
/-.'4-AAAAA
MACHINE NO. /CC-NO. /CLERK NAME 
2)/
MODE TITLE 
LANGUAGE MODE 
[Sample]
ST
89
TL
*'#&'4
2/
DATE/TIME/CLERK NO 
/-.'4-AAAAA
MACHINE NO. /CC-NO. /CLERK NAME
2)/
MODE TITLE 
JOB# 