XE-A113 (serv.man2). XE-A113 Program Manual - Sharp ECR Service Manual (repair manual). Page 12

Read Sharp XE-A113 (serv.man2) Service Manual online

XE-A113 (V)
PROGRAM MODE
2 – 9
[JOB#11] LOGO PRINTING    -- A --
MRS = 5
[JOB#12] EURO Programming    -- AB --
MRS = 00
[JOB#13] The date of exchanging the currency between
LOCAL and EURO    -- XXXXXXXX --
MRS = 00000000 (DD/MM/YYYY)
DATE) XXXXXXXX :YYYYMMDD (Year-month-day) or
DDMMYYYY (Day-month-Year) or
MMDDYYYY (Month-day-Year)
[YYYY: 2000~2099]
[MM: 01~12]
[DD: 01~31]
00000000 = Function Inhibit
The date entry format complies with the applicable PGM-mode programming.
In case of date setting is 0, EURO date function is not work.
[JOB#14]  The Time (hour only) of exchanging the currency
between LOCAL and EURO    -- XX --
MRS = 00
XX : Hour (00~23)
[JOB#50] THERMAL PRINTER DENSITY CONTROL   -- XX --
MRS = 50
XX: density (00~99)
00 :   70 % for standard 
50 : 100 % (Standard density) 
99 : 130 % for standard  
[JOB#61] OTHERS1 PROGRAMMING    -- ABCDEFGH --
MRS = 00100112
[JOB#62] OTHERS2 PROGRAMMING   -- ABCDEFGH --
MRS = 01000000
A: LOGO MESSAGE CONTROL
A
3-LINE HEADER INSTEAD OF GRAPHIC LOGO
0
GRAPHIC LOGO ONLY
1
GRAPHIC LOGO AND 3-LINE FOOTER
2
6-LINE HEADER
3
GRAPHIC LOGO AND 3-LINE HEADER
4
3-LINE HEADER AND 3-LINE FOOTER
5
A: Automatic converting the unit price at EURO
A
YES
0
NO
1
B: The EURO CHANGING JOB at the date of exchang-
ing the currency between LOCAL and EURO.
B
Compulsory
0
Noncompulsory
1
A, B: Not used (Fixed at “00”)
C: Programming of MINUS dept/PLU
C
Disable
0
Enable
1
D: Fractional treatment
D
Round off (4-DOWN, 5-UP)
0
Raising to unit
1
Disregarding
2
E: 00 key or 000 key selection for 00 key position
E
00 key 
0
000 key
1
F: Time format
F
12hour 0
24hour
1
G: Date format
G
M-D-Y 0
D-M-Y
1
Y-M-D
2
H: TAB
H
0
0
0.0
1
0.00
2
0.000
3
A: Not used (Fixed at “0”)
B: ERROR BEEP for miss operation
B
LOCK ERROR
0
MISS OPERATION
1
C: Key catch sound
C
Yes 0
No
1
D: Buffered Keyboard 
D
Yes 0
No
1
E: VOID mode
E
Enable 0
Disable
1
F: Printing of VOID MODE in X2/Z2 report
F
Yes 0
No
1
G: Printing of VOID MODE in X1/Z1 report
G
Yes 0
No
1
H: Addition to the hourly total in VOID MODE
H
No
0
Yes 1
Page of 26