UP-600, UP-700 (serv.man25). UP600-700 Service Manual - Sharp ECR Service Manual (repair manual). Page 49

Read Sharp UP-600 / UP-700 (serv.man25) Service Manual online

13-2. MRS, SRV reset
The UP-600/700 does not have the mode switch. The procedure for
resetting MRS, SRV is different from that of conventional cash regis-
ters.
in the UP-600/700, MRS, SRV resetting is selected and executed by
the key which has bee depressed when the CKDC reset is released
to start the system.
(In the case of MRS, security is added by a key operation equivalent
to a pass word.)
Flow chart
14. Drawer
The UP-600/700 can use up to 2 optional external drawers.
14-1. Drawer solenoid drive
P34 
 P37  inside  the  CPU  are  allocated  for  the  port  output  of  the
drawer solenoid drive.
Built-in port
Signal name
Remarks
P34
DR0
Drawer 1 (optional drawer)
P35
DR1
Drawer 2 (optional drawer)
P36
DR2
Reserved
P37
DR3
Reserved
One port corresponds to one drawer. Theoretically, it is possible to
drive multiple drawers at the same time, but this processing must be
inhibited softwarewisely because of power supply capacity and driver
hardware factors. If a power failure is detected, the drawer solenoid
drive must be stopped as soon as possible.
The drawer solenoid drive time must controlled in the range of 40
ms to 50 ms by the timer.
14-2. Drawer open/close sense
The drawer open/close sense signal is input into the built-in port of
the CPU. the sense signal of an optional drawer sensor is also wired
ORed before inputting.
P33=1: Any of the drawers is open.
15. TCP/IP STACK
The LAN of the UP-600/700 uses as a protocol Ethernet, which sup-
ports TCP/IP.
The interface with the TCP/IP board is achieved through 2 interrupt
signals and dual-port RAM.
The decode of dual-port RAM is located in the following space:
DP-RAM: F20000H - F2FFFFH (max. 64 KB)
The interruption from the TCP/IP is allocated as follows:
EXINTO: INTSW (SLAVE WRITE interrupt) bit 6 of 00FF81H
EXINT1: INTSR (SLAVE READ interrupt) bit 0 of 00FF80H
<TCP/IP connector terminals>
Signal Name
Pin No.
Pin No.
Signal Name
+5V
2
1
+5V
+5V
4
3
+5V
A14
6
5
A15
A12
8
7
A13
HWR
10
9
DPCS
A10
12
11
A11
A0
14
13
RD
A2
16
15
A1
A4
18
17
A3
A6
20
19
A5
A8
22
21
A7
D7
24
23
A9
D5
26
25
D6
D3
28
27
D4
D1
30
29
D2
LRES
32
31
D0
INTSW
34
33
INTSR
-
36
35
-
GND
38
37
GND
GND
40
39
GND
16. RS232
Two standard RS232 channels are compatible with the ER-A5RS.
However, while the ER-A5RS uses the IRQ2 terminal of the CPU for
interruption of the RS232, the UP-600/700 cannot use the IRQ1 ter-
minal instead of it. (The IRQ2 terminal is used for IR as the SCK1
terminal.)
The standard RS232 is fixed to the logic channels 1 and 8. Use the
channels 2,  3, 4, 5, 6 and 7 for the ER-A5RS.
17. MCR
This paragraph describes MCR option (UP-E13MR) control defined
by UP-600/700 hardware architecture.
3 channels of the serial port (interchangeable with 8251) built in the
MPCA9 are used. 3 tracks of data are read simultaneously. Supports
the first and second tracks MCR of ISO. (UP-E13MR)
Yes 
No 
*Slide Switch 
 operation 
MRS1 key 
ON? 
MRS2 key 
ON? 
CKDC start 
SRV reset 
MRS reset 
Start
Normal 
start? 
condition read 
Recovery 
No 
Yes 
OK? 
OK? 
SRV reset 
SRV reset 
No 
Yes 
Yes 
No 
Yes 
Yes 
No 
Hard reset 
start? 
PASSWORD 
judgement 
judgement 
10-key position 
input sequence 
MRS reset 
PASSWORD 
Page of 51
Display

Click on the first or last page to see other UP-600 / UP-700 (serv.man25) service manuals if exist.