UP-600, UP-700 (serv.man23). UP600-700 Program Manual - Sharp ECR Service Manual (repair manual). Page 12

Read Sharp UP-600 / UP-700 (serv.man23) Service Manual online

[01 DEVICE CONFIG] - [01 R/J PRINTER]
DISPLAY: Setting screen
[R/J PRINTER] (Built-in printer programming)
DISPLAY
CONTENTS
SELECT ITEM
MRS
NOTE
LIGHT&SHADE
Light & shade of printing
00-99
50
00= 75% for standard
50= 100% <Standard>
99= 125% for standard
IMAGE FOOTER
Footer Graphic LOGO print
NOT PRINT
NOT PRINT
PRINT
AUTO CUTTER
Auto cutter function
YES
YES
NO
RCPT LENGTH
Minimum length for bill on receipt 
00 - 30 lines
00
[01 DEVICE CONFIG] - [02 SLIP PRINTER]
DISPLAY: Setting screen
[SLIP PRINTER]
DISPLAY
CONTENTS
SELECT ITEM
MRS
NOTE
TERMINAL#
Terminal No.
000-254
000
000 : Self terminal No.
This means local device.
1-254: Except self terminal No.
This means re-routed device.
Re-routing programming is only valid for printer.
CHANNEL#
Channel No.
0-7
0
0: No RS232 channel is assigned.
1-7: RS232 channel is assigned.
PRINTER
Connected printer name
TM-295
TM-295
TM-T88/85
TM-T88 (2)
TM-U210
INITIAL FEED#
Initial SLIP feed line number
00-64
00
SLIP MAX LINE
Slip print maximum line No.
00-99
99
VP PRINT TIMES
No. of times of validation print
0-9
1