UP-600, UP-700 (serv.man23). UP600-700 Program Manual - Sharp ECR Service Manual (repair manual). Page 14

Read Sharp UP-600 / UP-700 (serv.man23) Service Manual online

[01 DEVICE CONFIG] - [12 BCR(SCANNER)]
DISPLAY: Setting screen
[BCR (SCANNER)]
DISPLAY
CONTENTS
SELECT ITEM
MRS
NOTE
CHANNEL#
Channel No.
0-7
0
0: No RS232 channel is assigned.
1-7: RS232 channel is assigned.
BAUD RATE
Transmission speed
4800 bps
4800 bps
9600 bps
19200 bps
DATA BITS
Data bit
7 Bits
7 Bits
8 Bits
PARITY
Parity bit
NON
ODD
EVEN
ODD
STOP BIT
Stop bit
2 Bits
1 Bit
1 Bit
ER-A6HS1 setting : "BAUD RATE = 4800 bps" , "DATA BITS = 7Bits", "PARITY = ODD", "STOP BIT = 1Bit"
NOTE: 1. Set the channel No. so that it does not conflict with other devices that are to be connected. If it does, the unit won’t operate normally.
2. Do not use channel No. 2 for the ER-A6HS1. Use other channel Nos.
3. If you want to change the channel No. of the BCR (Scanner), set a channel No. that is other than 0 and does not conflict with other
devices.
[01 DEVICE CONFIG] - [13 SCALE]
DISPLAY: Setting screen
[SCALE]
DISPLAY
CONTENTS
SELECT ITEM
MRS
NOTE
CHANNEL#
Channel No.
0-7
0
0: No RS232 channel is assigned.
1-7: RS232 channel is assigned.
NOTE: 1. Set the channel No. so that it does not conflict with other devices that are to be connected. If it does, the unit won’t operate normally.