Read Sharp ER-A570 (serv.man7) Service Manual online
6. Options
For installation of the options, refer to the Installation Manual which is
separately issued from this manual.
separately issued from this manual.
7. How to use service tools
7-1. SIO loop back connector: UKOG-6704RCZZ
•
External view
Fig. 7-1
•
Purpose: Used for "SIO Test 1 (SIO loop back test)."
•
Installation view:
Fig. 7-2
•
How to use: Connect the UKOG-6704RCZZ to the body and per-
form the following key operations:
SRV mode: 117
→
TL
7-2. Expansion PWB: CKOG-6708RCZZ
•
External view
Fig. 7-3
Purpose 1: Used for servicing and repairing of options (such as the
ER-A6IN and the ER-A5RS) which are connected with
the main body option connector.
the main body option connector.
[Procedure 1]
Use an insulator base as that in Fig. 7-4 (shaded section) and per-
form servicing.
Use an insulator base as that in Fig. 7-4 (shaded section) and per-
form servicing.
Fig. 7-4
To check the option I/F PWB from the solder side, connect the I/F
PWB to OPTCN2. To check from the parts side, connect to OPTCN3.
PWB to OPTCN2. To check from the parts side, connect to OPTCN3.
(Note) The option I/F PWB should be held horizontally so that no
excessive stress is applied to connecting section
Α
in Fig.
7-4.
[Procedure 2]
Fig. 7-5
As shown in Fig. 7-5, put a string between the pop up and the option
PWB angle and adjust the length of the string so that the CKOG-
6708RCZZ and the option PWB. Then perform servicing.
PWB angle and adjust the length of the string so that the CKOG-
6708RCZZ and the option PWB. Then perform servicing.
Purpose 2: The CKOG-6708RCZZ is equipped with the loop back
connector for checking the ER-A5CB (SIO cable) cable
operations.
operations.
Fig. 7-6
Checking procedure
1) Connect the ER-A5CB between an ECR body and the CKOG-
6708RCZZ SIOCN1. (The SIO functions of the ECR must be nor-
mal.)
mal.)
2) Perform test function "117 (SIO loop back test)" and judge it nor-
mal or abnormal.
Signal
Pin
GND
1
ER
2
DR
3
RXD
4
TXD
5
CD
6
RR
7
CS
8
R S
9
N.C
ER-A570
Main PWB
Expansion PWB
(CKOG-6708RCZZ)
ER-A5RS/A6IN
PWB
Loop back connectors (2 pcs.):
UKOG-6705RCZZ
Base
Control ROM
A
ER-A610
Main PWB
Expansion PWB
(CKOG-6708RCZZ)
ER-A5RS/A6IN
PWB
Control ROM
Pop up
String
Loop back connectors (2 pcs.):
UKOG-6705RCZZ
Example of use
ER-A570
SIO connector
CKOG-6708RCZZ
SIOCN1
ER-A5CB
7