SERVICE MANUAL
CODE: 00ZERA570VSME
ELECTRONIC
CASH REGISTER
MODEL 
ER-A570
SRV Key :  LKGIM7113RCZZ
PRINTER : M-820
(For "V" version)
CAUTION
EXTREME CAUTION MUST BE TAKEN WHEN SERVICING THIS MACHINE. EVEN
THOUGH THE MODE SWITCH IS IN THE 
&
 POSITION, VOLTAGE IS STILL SUPPLIED TO
THE ENTIRE MACHINE.
WHEN WORKING ON THIS MACHINE MAKE SURE THAT THE POWER CORD IS
REMOVED FROM THE WALL OUTLET.
CHAPTER 1. SPECIFICATIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1
CHAPTER 2. OPTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5
CHAPTER 3. SRV. RESET AND MASTER RESET . . . . . . . . . . . . . . . . . . . . . .  8
CHAPTER 4. HARD WARE DESCRIPTION. . . . . . . . . . . . . . . . . . . . . . . . . . . .  9
CHAPTER 5. TEST FUNCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  29
CHAPTER 6. DOWN LOAD FUNCTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  38
CHAPTER 7. SERVICE PRECAUTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  40
CHAPTER 8. CIRCUIT DIAGRAM & PWB LAYOUT . . . . . . . . . . . . . . . . . . . .  42
PARTS GUIDE
CONTENTS
SHARP CORPORATION
This document has been published to be used
for after sales service only.
The contents are subject to change without notice.
Parts marked with "
!
" is important for maintaining the safety of the set. Be sure to replace these parts with specified ones for
maintaining the safety and performance of the set.
CHAPTER 1. SPECIFICATIONS
1. Appearance/Rating
1) Appearance
Fig. 1-1
Fig. 1-2
2) Rating
Power source
AC local voltage (
±
10%) 50Hz/60Hz
Power consumption
Standby:
20 W
Maximum: 40 W(Germany), 40 W(U.K), 
with options installed.
Operating temperature
0°C~40°C (32°F~104°F)
Operating humidity
10%~90% (RH)
Physical dimensions,
including the drawer
445(W) 
 485(D) 
 325(H)mm
Weight
17.8 kg
2. Keyboard
Journal window
Printer cover
Receipt tape
Validation opening
Ribbon cover
Drawer lock
Keyboard
Drawer
Customer display
(Pop-up type)
Operator display
Mode switch
Power switch
Receipt ON/OFF
switch
1) Standard keyboard layout
Fig. 2-1
RECEIPT
CLK
1
16
11
6
1
17
12
7
2
18
13
8
3
19
14
9
4
20
15
10
5
#
10
9
8
7
6
5
4
3
2
1
20
19
18
17
16
15
14
13
12
11
30
29
28
27
26
25
24
23
22
21
40
39
38
37
36
35
34
33
32
31
50
49
48
47
46
45
44
43
42
41
60
59
58
57
56
55
54
53
52
51
70
69
68
67
66
65
64
63
62
61
80
79
78
77
76
75
74
73
72
71
JOURNAL
CLK
2
CLK
3
CLK
4
CLK
5
CLK
6
L3
L2
L1
PRICE
SHIFT
CR2
CR1
CH
TL
ST
N S
000
00
0
TL
RF
EX1
PLU/
SUB
3
2
1
RA
PO
NBAL
AMT
6
5
4
GLU
DEPO
(-)
9
8
7
%2
%1
DEPO
(+)
1
2
NC
CL
VAT
VAT
SHIFT
X
GUEST
#
AUTO
G C
COPY
VP
SLIP
RCPT
Validation opening
Printer cover lock
 1 
2) Key top name
1
Standard key top
Keytop
Description
0 to 9, 00, 000
Numeric keys
Decimal point key
C L
Clear key
Multiplication key
DEPT. 1~20
Department 1~20 keys
 RECEIPT
Receipt paper feed key
 JOURNAL
Journal paper feed key
RCPT
Receipt print key
VP
Validation print key
#
Non-add code entry key
AUTO
Atutomatically entry key
NS
No sale key
VAT
Value added tax key
SLIP
Slip print key
GC COPY
Guest check copy key
 1
Discount 1 key
 2
Discount 2 key
% 1
% 1 key
% 2
% 2 key
PO
Paid out key
RA
Received on account key
RF
Refund key
Void key
AMT
Amount key
PLU/SUB
PLU/Subdept. code entry key
EX1
Currency Exchange 1 keys
PLU 1~80
Direct/Sub department 1~80 keys
ST
Tax included subtotal key
CR 1
Credit 1 key
CR 2
Credit 2 key
CH
Check key
TL
Total key
VAT SHIFT
VAT Shift key
GUEST #
Guest number entry key
CLK1~6
Clerk 1~6 keys
L1~3
Level 1~3 keys
Price shift
Price shift key
DEPO (+)
Deposit (+) key
DEPO (–)
Deposit (–) key
NC
New check key
GLU
Guest look up key
NBAL
New balance key
2
Option key top
Keytop
Description
DEPT. 21~99
Department 21~99 keys
PLU 81~158
Direct/Sab department 81~158 keys
 3, 4
Discount 3 and 4 keys 
% 3, 4
%3 and 4 keys
CR3~8
Credit 3~8 keys
CA 2
Cash 2 key
EX 2~9
Currency Exchang 2~9 keys
AUTO 2 ~10
Automatically entry key 2~10
1/2
1/2 key
CH2 ~ CH4
Check2 ~ 4 keys
CLK7 ~ CLK10
Push button clerk7 ~ 10 keys
2nd PRICE
Second price entry key
RA2
Received account 2 key
PO2
Paid out 2 key
DEPT#
Department nimber entry key
CHK PR
Check print key
SCALE
Scale key
DIFF ST
Differ subtotal key
CLK#
Clerk number key
FINAL
Tentative finalize key
PINT
Pint key
B. T.
Bill totalizing key
B. S.
Bill separate key
3. Mode switch
Fig. 3-1
The key can be removed in the REG or OFF position.
In the SRV’ mode, key inputs are prohibited and no display is
made. 
With the key in the off position power is still supplied to the
main PWB.
[Functions]
Function for each key position
SRV’:
System reset
SRV:
Service mode (Service programming)
PGM2:
Allows programming of an item that is not changed
frequently, in addition to the PGM1 mode program-
ming.
SRV
MA
SM.
OP
REG
PGM1
PGM2
MGR
OP X/Z
(SRV)
(SRV')
X2/Z2
X1/Z1
 2 
PGM1:
Allows programming of items frequently changed
(e.g. department, PLU pricing, and discount rate set-
ting).
OP/XZ:
Allows X or Z operation by servers or cashiers.
REG:
Allows registrations.
MGR:
Allows the operations, by authorized person such as
a manager (e.g. correction after transaction finished
or cancellation of entry limits), which are not permit-
ted to ordinary cashiers.
X1/Z1:
Allows reading and resetting of a day’s sales total.
X2/Z2:
Allows reading or resetting sales totals in a specified
period.
• &
 :
Switching off the display to prevent key board en-
tries. 
(The setting does not turn off the AC
power.)
4. Display
1) Layout
1
Operator display
Fig. 4-1
Dot display
No. of positions
16
Color of display
Green
Character size
8.15 (H) 
 5.75 (W) mm
Font
Dot matrix (5
7)
2
Customer display
Fig. 4-2
No. of positions
7
Color of display
Green
Character size
13(H) 
 6(W) mm
Font
7 segments
Lamps
Display
contents
Description
ON LINE
The lamp lights up when the machine is connected
to the online transmission line; and it goes off when
the machine is disconnected from the line. The
lamp blinks during data transmission.
IN LINE
The lamp lights up during inline communications.
G. C. COPY
The lamp is on while the machine is in the GUEST
CHECK COPY mode.
GLU
The lamp lights up when a NC (New check) or
PBLU key depressed, and it goes off when a
transaction operation is finalized.
PLU
The lamp lights up when a PLU entry is made.
VAT SHIFT
The lamp lights up when the VAT SHIFT key is
pressed.
2nd PRICE
The lamp lights up when the 2nd PRICE key is
pressed.
L2
The lamp lights up when the PLU level is 2.
L3
The lamp lights up when the PLU level is 3.
The lamp lights up when the change due is
displayed after an amount tendered entry.
ST
The lamp lights up when a subtotal is displayed.
TL
The lamp lights up when a transaction is finalized
with CASH, CHECK, CREDIT, or CHARGE key,
however, the lamp does not light up when a
transaction is finalized with an amount tendered
entry. 
VOID
The lamp lights up when a void key entry is made.
RF
The lamp lights up when a RF key entry is made.
4
ON
LINE
1
2
3
5
6
7
8
11
10
9
12
13
14
15
16
IN
LINE
G.C.
COPY
GLU
PLU
VAT
SHIFT
2nd
PRCE
L2
L3
ST
TL
RF
4
1
2
3
5
6
7
TL
L2
RF
L3
ST
 3 
Page of 74
Display

Download Sharp ER-A570 (serv.man7) Service Manual (Repair Manual)

Here you can read online and download Sharp ER-A570 (serv.man7) Service Manual in PDF. ER-A570 (serv.man7) service manual will guide through the process and help you recover, restore, fix, disassemble and repair Sharp ER-A570 (serv.man7) ECR. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.