8) Attach the FG clamp 
8
 to the WMF cable and fix to the cable fixing
angle 
9
 with the screws 
Φ
. (Fig. 4)
Fig. 4
9) Pull out the WMF cable from the main body bottom to the inside of
the main body and fix the cable angle to the main chassis with the
screws 
Γ
. (Fig. 5)
Fig. 5
10) Fix the WMF cable to the lower cabinet with the clamp 
Η
 and
attach the ferrite core 
Ι 
to the cable withe the screw 
ϑ
. (Fig.6)
11) Connect the WMF cable to the WMF PWB. (Fig.6)
Fig. 6
12) Connect the locally purchased key body to the WMF cable. In
addition, the key body muat be connected with the WMF cable
grounding wire using the accessory grounding wire (QCNW–
7033RCZZ).
4. Operation test
1
Key operation
101 
 TL 
2
Functional description
Key, clerk, and receipt switch codes are displayed.
3
Check the following items:
Change key and switch positions for proper display activation.
Clerk code:
1 hole clerk key or WMF clerk key
000 (off state)
001 (Clerk 1)
002 (Clerk 2)
     
∗∗
255 (Clerk 255)
Receipt switch code:   0 (on state) 1 (off state)
Key code:
--- (simultaneous two key)
   depression, invalid entry)
   001 ~ 158
4
Test termination
Change the MODE switch position other than SRV position to
terminate the test. The test termination message is printed.
                        101
Test termination print
DOT DISPLAY :
C L
S W
K
Key code
Receipt SW code
Clerk code
8
9
10 : XHBSD30P08000
11
11 : LX-BZ6774RCZZ
12
13
14
: XBPSD30P06KS0
 21 
Page of 27