ER-A490 (serv.man2). ERA490 Service Manual - Sharp ECR Service Manual (repair manual). Page 41

Read Sharp ER-A490 (serv.man2) Service Manual online

CHAPTER 6. DOWNLOAD
FUNCTION
1. General
RAM data can be transmitted in the following two methods.
Save the data before servicing as follows:
1
ECR 
 ECR
2
ECR 
 ER-02FD
Note:
The ONL lamp on the display blinks during IR transmission.
If the ONL lamp goes off during transmission, it shows that
transmission is interrupted by a shift in the optical axis and
retrying process is being performed. To resume
transmission, adjust the optical axis. If the ON lamp blinks,
transmission is resumed. 
2. Communication between ECRs
1) The pop-up display of the ER-A490 is equipped with the IR inter-
face. Set the distance between IR interfaces within 75cm. Commu-
nication between ECRs is available in the ASK system and in the
IRDA system. 
Note: Set the memory size (JOB #971) and the transmission
baud rate (JOB #903) in the receive side and the send side
identically. 
ECR to ECR
|
: Enable
: Disable
Baud rate (bps)
ASK
IrDA
  2400
|
|
  4800
|
|
  9600
|
|
 19200
|
|
 38400
|
|
 57600
|
|
115200
|
1. Baud rate (bps)
903-A
  2400
2
  4800
3
  9600
4
 19200
5
 38400
6
 57600
7
115200
8
2) Communication sequence
1
Set the receiving ECR ready to receive. 
2
Set the sending ECR.
3) Transmission status.
Description of error status
 1: Application error (Command error)
  2: Line error (DTR OFF)
 3: Application error (Parity error)
  4: Application error (Check sum error)
  5: Application error (Data size error)
 6: Hard ware error
 7: Power off error
10: Time out error
11: Application error (Transmit data size error)
12: Application error (Block sequence error)
13: Memory full error
4) Service reset the receiving ECR.
3. Communication between an ECR and
the ER-01FD/02FD
1) The ER-A490 can perform IR communication by connecting the IR
interface (CE-IR2/IR4) to the FD unit (ER-01FD/02FD). The trans-
mission is made only in the ASK system. 
2) ER-01FD/02FD ROM replacement
To perform IR communication with the ER-01FD or the ER-02FD,
the control ROM must be replaced. 
New control ROM version for IR communication 
Version No.
Parts code
ER-01FD
R261C
VHI27256R261C
ER-02FD
RAG1D
VHI27256RAG1D
3) Connection between the ER-01FD/02FD and the CE-IR2/IR4
Make the connection cable and connect the FD unit and the IR
interface. 
Connection cable wiring
ECR
ECR
ECR
CE-IR2 or
CE-IR4
ER-02FD
TL
ABCD
0
903
Baud rate setting
x
TL
998
x
ST
: ASK system
: IRDA system
996
X
All data
X: SSP data = 0
: ASK system
: IRDA system
x
TL
ST
Frame Ground
1
SD
2
RD
3
RS
4
CS
5
DR
6
Signal Ground
7
ER
20
DB-25 MALE CONNECTOR
Frame Ground
TXD
RXD
RS
Signal Ground
DB-25 MALE CONNECTOR
1
2
3
4
5
6
7
20
ER-01FD/02FD side
CE-IR2/IR4 side
– 39 –
Page of 57
Display