ER-A490 (serv.man2). ERA490 Service Manual - Sharp ECR Service Manual (repair manual). Page 39

Read Sharp ER-A490 (serv.man2) Service Manual online

[12] Printer CG print
1
Key operation
119 
 TL 
2
Content
The built-in characters are printed.
After printing each line, the mode switch is checked. If the switch is
set to another position than SRV mode, the program is stopped.
If the mode switch is set to SRV mode, printing is continued.
The standard characters are printed in 16 characters/line, and the
expanded characters (double-width characters) are printed in 8
characters/line.
First the standard characters are printed, then the expanded char-
acter.
3
Check content
The output print is checked to check that the CG’s are normally
printed.
4
Cancel
When any key is pressed, the operation is terminated after com-
pletion of one cycle. Or set the mode switch to another position
than SRV mode.
[13] Standard RAM test
1
Key operation
120 
 TL 
2
Functional description
Perform the following check for the standard RAM 64 KByte
SRAM. The memory contents should not be changed before and
after the check.
Perform the following processes for  memory address to be
checked (1F0000H~1FFFFFH).
PASS1: Save memory data.
PASS2: Write data "0000H."
PASS3: Read and compare data "0000H," write data "5555H."
PASS4: Read and compare data "5555H," write data "AAAAH."
PASS5: Read and compare data "AAAAH."
PASS6: Restore the memory data.
If a compare error occurs in the check sequence PASS1-PASS6,
an error print is made. If no error occurs through all address, the
check ends normally.
The following address check is performed further.
Check point address = 1F0000H, 1F0001H
1F0002H, 1F0004H
1F0008H, 1F0010H
1F0020H, 1F0040H
1F0080H, 1F0100H
1F0200H, 1F0400H
1F0800H, 1F1000H
1F2000H, 1F4000H
1F8000H
3
Check the following items:
Check the termination printout.
4
Test termination
The test terminates after printing the termination printout.
Termination printout:
 Normal termination
120 
  Abnormal termination
  Ex – – – – –
120 
@@@@@ 
X = 01: Data check error
02: Address check error
Note: When an error occurs, the error print is performed and the
check is terminated. The error occurrence address is shown in
hexadecimal at positions shown with 
@@@@@
.
[14] Standard ROM test
1
Key operation
130 
 TL 
2
Functional description
Sum check of the standard ROM (C00000H - C7FFFFH) is per-
formed. If the lower two digits of SUM is 10H, it is normal. 
3
Check the following items:
Check the printout after the test.
4
Test termination
The test automatically terminates with termination message.
Normal termination print
 
130 
 ROM
27040@@@@@ 
@@@@@ 
        
Error termination print
  E – – – –  
130 
 ROM 
27040@@@@@ 
@@@@@ 
        
Note:  "
@@@@@
" means the ROM version number. 
The underlined section (10 bytes) of code table is provided in
the ROM as a standard and the table content is always printed.
The table position is the upper 10 digits of the ROM address.
The check sum correction address is the last address -0FH.
[15] A/D conversion check
1
Key operation
151 
 GOT 
2
Contents
The digital conversion value of the input signal to the CPU  A/D
convertor is displayed sequentially. The display channel is
changes is approx. 1 sec. interval by timer control and is displayed
repeatedly.
Thermistor input
Vrf input: Vrf means the presumed voltage of VRF when VCC is
supposed to be +0.5V.
1
1 9
7-SEGMENT DISPLAY:
C
G
P R I N T
S
DOT DISPLAY:
R V
1
2 0
7-SEGMENT DISPLAY:
S
- R A M
T S
S
DOT DISPLAY:
R V
1
3 0
7-SEGMENT DISPLAY:
S
- R A M
T S
S
DOT DISPLAY:
R V
1
5 1
1
7-SEGMENT DISPLAY:
T
M
=
S
DOT DISPLAY:
R V
* * * *
* * * *
– 37 –
Page of 57