ER-A490 (serv.man2). ERA490 Service Manual - Sharp ECR Service Manual (repair manual). Page 40

Read Sharp ER-A490 (serv.man2) Service Manual online

+24V input
Note: "XXXXX": The 10 bit data of the A/D convertor displayed in
decimal number.
Therefore, its connect may be 0000 
 1024.
3
Confirmation
Check the display content.
4
Termination
To when the mode switch is set to any mode other than SRV
mode, the termination print is made and the test is terminated.
                        151
Test termination print
[16] Option RAM test
1
Key operation
200 or 201 
 TL 
JOB
#NO.
RAM NO.
Memory to be
checked
Address area to be
checked
200
Option RAM
ER-02RA
200000H 
 21FFFFH
201
ER-03RA
200000H 
 27FFFFH
2
Content
The following check are performed for the optional RAM.
The following process is performed for memory addresses  to be
checked. 
PASS1: memory data save
PASS2: Data "0000H" write
PASS3: Data "0000H" read and comparison, data "5555H" write
PASS4: Data "5555H" read and comparison, data "AAAAH" write
PASS5: Data "AAAAH" read and comparison
PASS6: Memory data restore
If a compare error is found in the check sequence from PASS1 to
PASS6, error print (error code E1) is performed. If there is no error
found to the end of the last address, the operation is completed
normally.
Then the following address check is performed. "
|
" shows a valid
address, and "
" shows an invalid address.
In case of an error, error code E2 is printed.
Check Address
JOB#200
(ER-02RA)
JOB#201
(ER-03RA)
200000H
F
F
200001H
F
F
200002H
F
F
200004H
F
F
200008H
F
F
200010H
F
F
200020H
F
F
200040H
F
F
200080H
F
F
200100H
F
F
200200H
F
F
200400H
F
F
200800H
F
F
201000H
F
F
202000H
F
F
204000H
F
F
208000H
F
F
210000H
F
F
220000H
F
240000H
F
260000H
F
3
Check the following items.
Check the termination print. 
4
Test termination
The test terminates after printing the termination printout. 
Termination print
E01---
200
(ER-02RA data check error)
E02---
200
(ER-02RA address check error)
*****
E01---
200
(ER-03RA data check error)
E02---
201
(ER-03RA address check error)
******
E01---
200
(ER-02RA normal end)
E02---
201
(ER-03RA normal end)
******
: Error address
[17] Option ROM test
1
Key operation:
400 
 TL 
2
Functional description:
A sum check is done for the option ROM (Address hex C80000H
thru C9FFFFH.)
3
Check the following items:
Check the termination printout.
4
Test termination:
The test terminates after printing the termination printout.
Termination printout
 Normal termination
400 
 ROM
27010@@@@@ 
@@@@@ 
      
  E – – – – –
400 
 ROM
27010@@@@@ 
@@@@@ 
       
The underlined section must be the same as the standard ROM
test specification. (Refer to JOB #130.)
1
5 1
2
7-SEGMENT DISPLAY:
V
R
=
S
DOT DISPLAY:
R V
* * * *
* * * *
F
1
5 1
3
7-SEGMENT DISPLAY:
V
P
=
S
DOT DISPLAY:
R V
* * * *
* * * *
2
7-SEGMENT DISPLAY:
4
0
7-SEGMENT DISPLAY:
O
- R O M
T S
S
DOT DISPLAY:
R V
*
– 38 –
Page of 57
Display