ER-A450S (serv.man5). Service Manual - Sharp ECR Service Manual (repair manual). Page 37

Read Sharp ER-A450S (serv.man5) Service Manual online

out occurs irrespective of any errors that have occurred during the
check. (The program terminates normally only when no error print-out
has occurred.)
ERROR ERROR PRINT
Contents
1
E1-ER  DR
ERn-DRn ERR
2
E2-ER  CI
ERn-CIn ERR
3
E3-RS CD
RSn-CDn ERR
4
E4-RS CS
RSn-CSn ERR
5
E5-CI INT
Interruption error of CIn
6
E6-CD INT
Interruption error of CDn
7
E7-CS INT
Interruption error of CSn
8
E8-TXEMP
TXEMPn error
9
E9-TXEMP I
Interruption error of TXEMPn
10
E10-TXRDY
TXRDYn error
11
E11-TXRDY I
Interruption error of TXRDYn
12
E12-RCVRDY
RCVRDYn error
(Reception is impossible. TRQ1 has
occurred during execution of check 
.)
13
E13-RCVRDY I
Interruption error of RCVRDY
14
E14-SD RD
SDn-RDn ERR
(Data error)
15
E15-SD RD
SDn-RDn ERR
(Data error, Flaming error)
16
E16-TIMER
TIMERn error
(TMRQn cannot be set after
termination of check 
.)
17
E17-TIMER I
Interruption error of TRQ1
Errors that may occur during check 
 
(control signal check): E1
 E7
Errors that may occur during check 
 (data transfer check): E8
 E15
Errors that may occur during check 
 (timer check): E12, E16 and
E17
4) Test termination
The program automatically terminates when a check is finished.
  Termination print-out:
 
50nn 
   
nn  :  01 or 50
Ref.:Print generated when an error occurs
When no communication is established:
(w/o loopback connector)
Diag #550 (ch8)
Diag #501 (ch1)
Contents of print
Print of an error
encountered first
The contents of prints are different even if the error is the same.
5 – 7
Page of 42
Display

Click on the first or last page to see other ER-A450S (serv.man5) service manuals if exist.