2) Content
The following check are performed for the optional RAM.
The following process is performed for memory addresses to be
checked. 
PASS1: memory data save
PASS2: Data "0000H" write
PASS3: Data "0000H" read and comparison, data "5555H" write
PASS4: Data "5555H" read and comparison, data "AAAAH" write
PASS5: Data "AAAAH" read and comparison
PASS6: Memory data restore
If a compare error is found in the check sequence from PASS1 to
PASS6, error print (error code E1) is performed. If there is no error
found to the end of the last address, the operation is completed
normally.
Then the following address check is performed. " " shows a valid
address, and "
" shows an invalid address.
In case of an error, error code E2 is printed.
Check Address
JOB#201(ER-03RA)
200000H
|
200001H
|
200002H
|
200004H
|
200008H
|
200010H
|
200020H
|
200040H
|
200080H
|
200100H
|
200200H
|
200400H
|
200800H
|
201000H
|
202000H
|
204000H
|
208000H
|
210000H
|
220000H
|
240000H
|
260000H
|
3) Check the following items.
Check the termination print. 
4) Test termination
The test terminates after printing the termination printout. 
Termination print
E1---
200
(data check error)
E2---
200
(address check error)
200
(normal end)
: Error address
[15] RS-232 Channel 1 check
[16] RS-232 channel 8 check
Loop back connector for D-SUB 9pin : UKOG-6705RCZZ
1) Key operation check
The program is activated by JOB#501 or JOB#550
SRV mode: 501 
 TL  : Channel 1
550 
 TL  : Channel 8
2) Functional descripiton
If the channel specified by JOB#CODE is not set, the machine per-
forms the mis-operation processing. When the channel is set, the
machine conducts the loop check concerning the channel specified
by JOB#CODE by using the loopback connector.
The following three items are checked:
Control signal check
Data transfer check
Timer check (RS-232 onboard timer)
Check 
Control signal check (ERn-DRn
CIn, RSn-CDn
CSn loop check)
OUTPUT
INPUT
ERn
RSn
DRn
CIn
CDn
CSn
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
ON
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
The read check about the above INPUT items and interrupt check of
CS, CI and CD are performed.
Read check:
ER and RS are switched over in the order as
shown in the above table to confirm the logic of
DR, CI, CD and CS.If the read logic is different
from the one in the table, error print-outs occur.
Interrupt check: Allows the interruption of either of CS, CI and CD
one by one. (The mask is released.)
The interruption does not take place when each
signal is turned on. Or if the interruption occurs
when a signal is turned off, error print-outs occur.
Each of the above checks should be made in four cycles.
Check 
Data transfer check (SDn-RDn loop check)
In this check, transfer 256-byte loopback data of $00
 $FF.
Note) The above check should be made with the baud rate set at
9600BPS.
Check 
Timer check
Before making check 
, set the corresponding timer at
10ms for RCVDT activation, and check to see that:
1) TRQ1 is not generated during the execution of  check
.
2) TRQ1 is generated in 10msec. after check 
  is    fin-
ished.
3) Check the followin item
If an error occurs during the above checks, following error print-outs
occur. Even if an error occurs during check 
, the test is continued
after the corresponding error print-out has occurred, but if an error
occurs during the execution of check 
 or 
, the test is terminated
after the corresponding error print-out has occurred.
Note that when check 
 or 
 terminates, the termination print-
2
0
7-SEGMENT DISPLAY:
0
SIGNAL NAME
CD
RD
SD
ER
GND
DR
RS
CS
CI
1
2
3
4
5
6
7
8
9
PIN No.
5 – 6
Page of 42