ER-A410, ER-A420 (serv.man4). ERA410 420 Programming Manual - Sharp ECR Service Manual (repair manual). Page 40

Read Sharp ER-A410 / ER-A420 (serv.man4) Service Manual online

ER-A410/ER-A420
PROGRAM (PGM2/PGM1) MODE
2 – 25
3. PROGRAMMING BY DIRECT KEY
1) DEPT UNIT PRICE
MODE: PGM1, PGM2
If a price is set for a department which amount entry type is “INHIBIT” or
“OPEN”, its amount entry type is set as below automatically.
MRS = 0
2) (-) PRESET AMOUNT
MODE: PGM, PGM2
MRS = 0
3) DEPT FUNCTION PROGRAMMING
MODE: PGM2
YY: Department Code (01-99)
XXXXXX: Unit price (Max. 6 digits)
“PRESET”
”INHIBIT”
“OPEN & PRESET”
1
 ”OPEN”
YY: Department Code (01-99)
XXXXXX: Unit price (Max. 6 digits)
DPT n
0
XXXXXX
0
XXXXXX
YY
ST
TL
DEPT#
(-) n
0
XXXXXX
TL
YY: Department code (01-99)
A: Taxable 4
A
No
0
Yes
1
B: Taxable 3
B
No
0
Yes
1
C: Taxable 2
C
No
0
Yes
1
D: Taxable 1
D
No
0
Yes
1
E: ITEM VP
E
Non-compulsory
0
Compulsory
1
F: REGISTRATION TYPE
F
NORMAL
0
SICS
1
SIF
2
G: AMOUNT ENTRY TYPE
G
Inhibit
0
Open only
1
Preset only
2
Open & Preset
3
H: HALO Mantissa = 0 to 9
I: HALO Exponent = 0 to 8
H and I indicate A x 10
B
Except the value A and B, any amount over 99999999 can
not be entered.
J: Commission group = 0 to 9
KK: Department group = 00 to 14
Group 01 to 09 : Plus department
Group 10 : Minus department
Group 11 : Plus HASH department
Group 12 : Minus HASH department
Group 13 : Plus BR department
Group 14 : Minus BR department
MRS =  000100118001
(TAXABLE 1, VP Non-compulsory, NORMAL, Open only,
HALO = 17, Commission =0, Group =01)
DPT n
0
ABCDEFGHIJKK
0
ABCDEFGHIJKK
YY
TL
DEPT#
Page of 53
Display

Click on the first or last page to see other ER-A410 / ER-A420 (serv.man4) service manuals if exist.