ER-A410, ER-A420 (serv.man4). ERA410 420 Programming Manual - Sharp ECR Service Manual (repair manual). Page 37

Read Sharp ER-A410 / ER-A420 (serv.man4) Service Manual online

ER-A410/ER-A420
PROGRAM (PGM2/PGM1) MODE
2 – 22
[JOB#2643]
SLIP TEXT PROGRAMMING
1 BLOCK MAX. 24 CHARACTERS
[JOB#2646]
PAYEE NAME FOR ENGLISH CHECK PROGRAMMING
1 BLOCK MAX. 21 CHARACTERS
[JOB#2680]
PROGAMMING FOR EXCHANGE DRAWER
MRS = 0
[JOB#2681]
EURO FUNCTION
MRS = 000
[JOB#2682]
EURO DATE
Timing of changing the currency between LOCAL and EURO
The date entry format complies with SRV#912_A.
In case of date/time setting is 0, EURO date/time function is not work.
MRS = 000000
[JOB#2683]
EURO TIME (hour only)
Timing of changing the currency between LOCAL and EURO
MRS = 00
[JOB#2689]
POWER SAVING
MRS = 0030 
[JOB#2690]
THE ASSIGNMENT OF RS232 FUNCTION BY EACH DEVICES
X: Position code = 1 to 3
MRS = “Space”
“Space”
“Space”
X: Position code =1 to 2
MRS = “Space”
“Space”
X: DRAWER No.
X
Non
0
#1
1
#2
2
A: Automatic converting the unit price at EURO
A
Yes
0
No
1
B: The EURO CHANGE JOB at EURO DATE/TIME
B
Compulsory
0
Non-compulsory
1
C: EX1 Fractional treatment
C
Raising to unit
0
Rount off (4-DOWN, 5-UP)
1
2643
Characters
No change
SBTL
CA/AT
@/FOR
@/FOR
Position code
X
2646
Characters
No change
SBTL
TL
Position code
X
2680
X
0
TL
2681
ABC
TL
0
XXXXXXXX: DATE
(DATE) YYYYMMDD (Year-month-day) or
DDMMYYYY (Day-month-Year) or
MMDDYYYY (Month-day-Year)
[YYYY: 2000-2099] [MM: 01-12] [DD: 01-31]
HH: Hour (0-23)
X: POWER SAVING function when a time is displayed
X
Yes
0
No
1
YYY: POWER SAVING TIME to POWER OFF = 001-254 (minutes)
or 999 (Inhibit)
X: 1
MRS = 0000
A: Channel No. for on-line
A
Not connect
0
RS port 1
1
RS port 2
B, C, D:  Not used (Fixed at “000”)
2682
XXXXXXXX
0
TL
2683
HH
0
TL
2689
XYYY
TL
2690
ABCD
0
X
ST
TL
Page of 53